A statistical study of the errors involved in the sampling and chemical analysis of soils and plants, with particular reference to citrus and pineapples
- Steyn, Willem Johannes Abraham
- Authors: Steyn, Willem Johannes Abraham
- Date: 1958
- Subjects: Soil chemistry , Plants -- Analysis , Soils -- Analysis
- Language: English
- Type: Thesis , Doctoral , PhD
- Identifier: vital:4506 , http://hdl.handle.net/10962/d1013291
- Description: 1. Accurate and reproducible methods for the determination of N and acid- extractable P in soils are described. The variations in N, P, and K found by intensive sampling of three different soil types are presented. 3. Suggestions for the adequate sampling of soils for various purposes arc given. 4. A study is presented of the preparative stages in leaf analysis (washing, drying, grinding and storage) as applied to citrus and pineapple leaf material. Likely errors are pointed out and procedures whereby these may be minimised are described. 5. A reliable wet-ashing procedure for obtaining leaf solutions is described. 6. Accurate and reproducible methods for the determination of total N, P,. K, Ca, Mg, Na, Fe, Mn, Zn and Cu in citrus and pineapple leaves are presented. 7. It is shown that diurnal variations in nutrient concentrations occur in citrus and pineapple leaves. 8. The variations in N, P, K, Ca, Mg, Na, Fe, Mn, Zn and Cu, occurring from tree to tree in 3 different Navel orange blocks are presented. It is shown that if all these elements are to be represented . to within 10% of the mean values on a 19 : 1 probability level, all the trees in the blocks would have to be sampled. Reasonable sampling procedures for various purposes are suggested. 9. The variations in N, P, K, Ca, Mg, Fe, Mn, Zn and Cu, occurring in 3 different Cayenne pineapple plantations are presented and described. Suitable sampling procedures are suggested.
- Full Text:
- Date Issued: 1958
- Authors: Steyn, Willem Johannes Abraham
- Date: 1958
- Subjects: Soil chemistry , Plants -- Analysis , Soils -- Analysis
- Language: English
- Type: Thesis , Doctoral , PhD
- Identifier: vital:4506 , http://hdl.handle.net/10962/d1013291
- Description: 1. Accurate and reproducible methods for the determination of N and acid- extractable P in soils are described. The variations in N, P, and K found by intensive sampling of three different soil types are presented. 3. Suggestions for the adequate sampling of soils for various purposes arc given. 4. A study is presented of the preparative stages in leaf analysis (washing, drying, grinding and storage) as applied to citrus and pineapple leaf material. Likely errors are pointed out and procedures whereby these may be minimised are described. 5. A reliable wet-ashing procedure for obtaining leaf solutions is described. 6. Accurate and reproducible methods for the determination of total N, P,. K, Ca, Mg, Na, Fe, Mn, Zn and Cu in citrus and pineapple leaves are presented. 7. It is shown that diurnal variations in nutrient concentrations occur in citrus and pineapple leaves. 8. The variations in N, P, K, Ca, Mg, Na, Fe, Mn, Zn and Cu, occurring from tree to tree in 3 different Navel orange blocks are presented. It is shown that if all these elements are to be represented . to within 10% of the mean values on a 19 : 1 probability level, all the trees in the blocks would have to be sampled. Reasonable sampling procedures for various purposes are suggested. 9. The variations in N, P, K, Ca, Mg, Fe, Mn, Zn and Cu, occurring in 3 different Cayenne pineapple plantations are presented and described. Suitable sampling procedures are suggested.
- Full Text:
- Date Issued: 1958
Some measurements of the conductivities of dilute potassium chloride solutions
- Authors: Faure, Abraham
- Date: 1954
- Subjects: Potassium chloride
- Language: English
- Type: Thesis , Doctoral , PhD
- Identifier: vital:4471 , http://hdl.handle.net/10962/d1011787
- Description: A constant temperature room has been constructed in which the thermoregulator is controlled by a temperature-sensitive resistance. A thermostat has been constructed in which the 0 temperature is controlled to within 0.001°C. A precision conductance bridge has been built in a very convenient form. Improvements include the replacement of the telephone as null detector by a cathode ray oscilloscope, and the use of a resistance-capacity phase-shift oscillator, which gives a good wave-form. An automatic recycling conductance water still has been built which regularly gives water with a conductivity less than 0.09 micromhos per cm. The conductivities of dilute KCl solutions have been measured, taking special care to prevent errors due to the adsorption of KCl on the surface of glass. Two cells were used for these measurements : a modified Jones cell, and a special conductimetric titration cell. The modified Jones cell has given results in good agreement with the generally-accepted values. The results of the conductimetric titration cell do not agree well with the generally-accepted values; the greatest difference (for the most dilute solution) is 0.4%. The reason for this is not known.
- Full Text:
- Date Issued: 1954
- Authors: Faure, Abraham
- Date: 1954
- Subjects: Potassium chloride
- Language: English
- Type: Thesis , Doctoral , PhD
- Identifier: vital:4471 , http://hdl.handle.net/10962/d1011787
- Description: A constant temperature room has been constructed in which the thermoregulator is controlled by a temperature-sensitive resistance. A thermostat has been constructed in which the 0 temperature is controlled to within 0.001°C. A precision conductance bridge has been built in a very convenient form. Improvements include the replacement of the telephone as null detector by a cathode ray oscilloscope, and the use of a resistance-capacity phase-shift oscillator, which gives a good wave-form. An automatic recycling conductance water still has been built which regularly gives water with a conductivity less than 0.09 micromhos per cm. The conductivities of dilute KCl solutions have been measured, taking special care to prevent errors due to the adsorption of KCl on the surface of glass. Two cells were used for these measurements : a modified Jones cell, and a special conductimetric titration cell. The modified Jones cell has given results in good agreement with the generally-accepted values. The results of the conductimetric titration cell do not agree well with the generally-accepted values; the greatest difference (for the most dilute solution) is 0.4%. The reason for this is not known.
- Full Text:
- Date Issued: 1954
- «
- ‹
- 1
- ›
- »