Nanomaterial modified electrodes : optimization of voltammetric sensors for pharmaceutical and industrial application
- Authors: Brimecombe, Rory Dennis
- Date: 2011
- Subjects: Voltammetry , Electrochemistry , Nanotubes , Nanostructured materials
- Language: English
- Type: Thesis , Doctoral , PhD
- Identifier: vital:4101 , http://hdl.handle.net/10962/d1009721
- Description: Nanomaterials, in particular carbon nanotubes have been shown to exhibit favourable properties for the enhancement of electrochemical detection of target analytes in complex matrices. There is however scope for improvement in terms of the optimization thereof in electrochemical sensors surface modification. The aim of this thesis was to examine methods that would result in increased current response, lowered passivation and application of such modified surfaces with application to pharmaceutically and industrially relevant analytes. Current methods for enhancing the performance of carbon nanotubes include acid functionalization which not only increases the hydrophilicity of the nanotubes, and consequently their ability to provide stable (aqueous) suspensions, but also introduces electrochemically active sites. This particular approach is however not normalized in the literature. Over-exposure to acid treatment results in loss of structural integrity of the carbon nanotubes, and as such a fine balance exists between achieving these dual outcomes. Guided by high resolution scanning electron microscopy, atomic force microscopy, voltammetric and impedance studies, this thesis examined the role of the length of time of the acid functionalization process as well as the impact of activation of carbon nanotubes and fullerenes on electrochemical sensor performance. Based on desired charge transfer resistances, rate transfer coefficients and sensitivity towards redox probes the optimal length of acid functionalization for multiwalled carbon nanotubes was 9 hours and 4 hours for single-walled carbon nanotubes. Further improvements in the desired outcomes were achieved through electrochemical activation of the modified electrode surface by cycling in the presence of catechol, in a novel approach. By employing electrochemical impedance spectroscopy it was observed that catechol activation resulted in lowered charge transfer resistance, before and after activation, with functionalized multi-walled carbon nanotubes (9 hours) exhibiting the greatest decrease of 90 % and functionalized single-walled carbon nanotubes (4 hours), a 50 % decrease. Corresponding increases in the heterologous rate transfer coefficient showed a 770 % increase for functionalized multi-walled carbon nanotubes (9 hours), following catechol activation. Comparative observations for fullerenes following partial reduction in potassium hydroxide yielded a 30 % decrease in charge transfer resistance, with an increased heterologous rate transfer coefficient at a fullerene modified surface The performance of the nanomaterial modified electrodes was applied to the detection of wortmannin with applications in bioprocess control and in the pharmaceutical sector as well as to the detection and monitoring of the industrial dye Reactive red. Of particular relevance to these analytes was the assessment of the nanomaterial modified electrodes for enhanced stability, reproducibility, sensitivity and decreased passivation effects. In this study the first known account of wortmannin detection through electrochemical methods is reported. Voltammetric characterization of wortmannin revealed an irreversible cathodic process with a total number of 4 electrons and a diffusion coefficient of 1.19 x 10-7 cm².s⁻¹. At a functionalized multiwalled carbon nanotubes modified glassy carbon electrode a limit of detection of 0.128 nmol.cm⁻³ was obtained, and with limited surface passivation the detection scheme afforded pertinent analyses in biological media representing a substantial improvement over chromatographic detection methods. This study also provided the first account of the voltammetric detection of reactive red, competing favourably with traditional spectroscopic methods for monitoring biodegradation of this compound in real time.
- Full Text:
- Date Issued: 2011
- Authors: Brimecombe, Rory Dennis
- Date: 2011
- Subjects: Voltammetry , Electrochemistry , Nanotubes , Nanostructured materials
- Language: English
- Type: Thesis , Doctoral , PhD
- Identifier: vital:4101 , http://hdl.handle.net/10962/d1009721
- Description: Nanomaterials, in particular carbon nanotubes have been shown to exhibit favourable properties for the enhancement of electrochemical detection of target analytes in complex matrices. There is however scope for improvement in terms of the optimization thereof in electrochemical sensors surface modification. The aim of this thesis was to examine methods that would result in increased current response, lowered passivation and application of such modified surfaces with application to pharmaceutically and industrially relevant analytes. Current methods for enhancing the performance of carbon nanotubes include acid functionalization which not only increases the hydrophilicity of the nanotubes, and consequently their ability to provide stable (aqueous) suspensions, but also introduces electrochemically active sites. This particular approach is however not normalized in the literature. Over-exposure to acid treatment results in loss of structural integrity of the carbon nanotubes, and as such a fine balance exists between achieving these dual outcomes. Guided by high resolution scanning electron microscopy, atomic force microscopy, voltammetric and impedance studies, this thesis examined the role of the length of time of the acid functionalization process as well as the impact of activation of carbon nanotubes and fullerenes on electrochemical sensor performance. Based on desired charge transfer resistances, rate transfer coefficients and sensitivity towards redox probes the optimal length of acid functionalization for multiwalled carbon nanotubes was 9 hours and 4 hours for single-walled carbon nanotubes. Further improvements in the desired outcomes were achieved through electrochemical activation of the modified electrode surface by cycling in the presence of catechol, in a novel approach. By employing electrochemical impedance spectroscopy it was observed that catechol activation resulted in lowered charge transfer resistance, before and after activation, with functionalized multi-walled carbon nanotubes (9 hours) exhibiting the greatest decrease of 90 % and functionalized single-walled carbon nanotubes (4 hours), a 50 % decrease. Corresponding increases in the heterologous rate transfer coefficient showed a 770 % increase for functionalized multi-walled carbon nanotubes (9 hours), following catechol activation. Comparative observations for fullerenes following partial reduction in potassium hydroxide yielded a 30 % decrease in charge transfer resistance, with an increased heterologous rate transfer coefficient at a fullerene modified surface The performance of the nanomaterial modified electrodes was applied to the detection of wortmannin with applications in bioprocess control and in the pharmaceutical sector as well as to the detection and monitoring of the industrial dye Reactive red. Of particular relevance to these analytes was the assessment of the nanomaterial modified electrodes for enhanced stability, reproducibility, sensitivity and decreased passivation effects. In this study the first known account of wortmannin detection through electrochemical methods is reported. Voltammetric characterization of wortmannin revealed an irreversible cathodic process with a total number of 4 electrons and a diffusion coefficient of 1.19 x 10-7 cm².s⁻¹. At a functionalized multiwalled carbon nanotubes modified glassy carbon electrode a limit of detection of 0.128 nmol.cm⁻³ was obtained, and with limited surface passivation the detection scheme afforded pertinent analyses in biological media representing a substantial improvement over chromatographic detection methods. This study also provided the first account of the voltammetric detection of reactive red, competing favourably with traditional spectroscopic methods for monitoring biodegradation of this compound in real time.
- Full Text:
- Date Issued: 2011
Voltammetric analysis of pesticides and their degradation: A case study of Amitraz and its degradants
- Authors: Brimecombe, Rory Dennis
- Date: 2006
- Subjects: Hydrolysis , Biodegradation , Voltammetry , Pesticides -- Biodegradation , Pesticides -- Environmental aspects , Acaricides , Acaricides -- Physiological effect
- Language: English
- Type: Thesis , Masters , MSc
- Identifier: vital:4131 , http://hdl.handle.net/10962/d1015724
- Description: Amitraz is a formamide acaricide used predominantly in the control of ectoparasites in livestock and honeybees. Amitraz hydrolysis is rapid and occurs under acidic conditions, exposure to sunlight and biodegradation by microorganisms. The main hydrolysis product of amitraz, 2,4-dimethylaniline, is recalcitrant in the environment and toxic to humans. An electrochemical method for the determination of total amitraz residues and its final breakdown product, 2,4-dimethylaniline, in spent cattle dip, is presented. Cyclic voltammetry at a glassy carbon electrode showed the irreversible oxidation of amitraz and 2,4-dimethylaniline. A limit of detection in the range of 8.5 x 10⁻⁸ M for amitraz and 2 x 10⁻⁸ M for 2,4-dimethylaniline was determined using differential pulse voltammetry. Feasibility studies in which the effect of supporting electrolyte type and pH had on electroanalysis of amitraz and its degradants, showed that pH affects current response as well as the potential at which amitraz and its degradants are oxidised. Britton-Robinson buffer was found to be the most suitable supporting electrolyte for detection of amitraz and its degradants in terms of sensitivity and reproducibility. Studies performed using environmental samples showed that the sensitivity and reproducibility of amitraz and 2,4-dimethylaniline analyses in spent cattle dip were comparable to analyses of amitraz and 2,4-dimethylaniline performed in Britton-Robinson buffer. In addition, the feasibility qf measuring amitraz and 2,4-dimethylaniline in environmental samples was assessed and compared to amitraz and 2,4-dimethylaniline analyses in Britton-Robinson buffer. Amitraz and 2,4-dimethylaniline were readily detectable in milk and honey. Furthermore, it was elucidated that 2,4-dimethylaniline can be metabolised to 3-methylcatechol by Pseudomonas species and the proposed breakdown pathway is presented. The biological degradation of amitraz and subsequent formation of 2,4-dimethylaniline was readily monitored in spent cattle dip. The breakdown of amitraz to 2,4-dimethylaniline and then to 3-MC was monitored using cyclic voltammetry.
- Full Text:
- Date Issued: 2006
- Authors: Brimecombe, Rory Dennis
- Date: 2006
- Subjects: Hydrolysis , Biodegradation , Voltammetry , Pesticides -- Biodegradation , Pesticides -- Environmental aspects , Acaricides , Acaricides -- Physiological effect
- Language: English
- Type: Thesis , Masters , MSc
- Identifier: vital:4131 , http://hdl.handle.net/10962/d1015724
- Description: Amitraz is a formamide acaricide used predominantly in the control of ectoparasites in livestock and honeybees. Amitraz hydrolysis is rapid and occurs under acidic conditions, exposure to sunlight and biodegradation by microorganisms. The main hydrolysis product of amitraz, 2,4-dimethylaniline, is recalcitrant in the environment and toxic to humans. An electrochemical method for the determination of total amitraz residues and its final breakdown product, 2,4-dimethylaniline, in spent cattle dip, is presented. Cyclic voltammetry at a glassy carbon electrode showed the irreversible oxidation of amitraz and 2,4-dimethylaniline. A limit of detection in the range of 8.5 x 10⁻⁸ M for amitraz and 2 x 10⁻⁸ M for 2,4-dimethylaniline was determined using differential pulse voltammetry. Feasibility studies in which the effect of supporting electrolyte type and pH had on electroanalysis of amitraz and its degradants, showed that pH affects current response as well as the potential at which amitraz and its degradants are oxidised. Britton-Robinson buffer was found to be the most suitable supporting electrolyte for detection of amitraz and its degradants in terms of sensitivity and reproducibility. Studies performed using environmental samples showed that the sensitivity and reproducibility of amitraz and 2,4-dimethylaniline analyses in spent cattle dip were comparable to analyses of amitraz and 2,4-dimethylaniline performed in Britton-Robinson buffer. In addition, the feasibility qf measuring amitraz and 2,4-dimethylaniline in environmental samples was assessed and compared to amitraz and 2,4-dimethylaniline analyses in Britton-Robinson buffer. Amitraz and 2,4-dimethylaniline were readily detectable in milk and honey. Furthermore, it was elucidated that 2,4-dimethylaniline can be metabolised to 3-methylcatechol by Pseudomonas species and the proposed breakdown pathway is presented. The biological degradation of amitraz and subsequent formation of 2,4-dimethylaniline was readily monitored in spent cattle dip. The breakdown of amitraz to 2,4-dimethylaniline and then to 3-MC was monitored using cyclic voltammetry.
- Full Text:
- Date Issued: 2006
- «
- ‹
- 1
- ›
- »