Evaluation of the proposed FDA pilot-dose response methodology for topical corticosteroid bioeqivalence testing [authors' reply in Letters to the Editor]
- Smith, Eric W, Walker, Roderick B, Haigh, John M, Kanfer, Isadore
- Authors: Smith, Eric W , Walker, Roderick B , Haigh, John M , Kanfer, Isadore
- Date: 1998
- Language: English
- Type: text , Article
- Identifier: vital:6423 , http://hdl.handle.net/10962/d1006558
- Description: Reply to: Letter to the Editor by Singh GJ; Fleischer N; Lesko L; Williams R - relating to original article in Pharmaceutical Research (USA), Mar 1997, vol. 14, pp. 303-308.
- Full Text: false
- Authors: Smith, Eric W , Walker, Roderick B , Haigh, John M , Kanfer, Isadore
- Date: 1998
- Language: English
- Type: text , Article
- Identifier: vital:6423 , http://hdl.handle.net/10962/d1006558
- Description: Reply to: Letter to the Editor by Singh GJ; Fleischer N; Lesko L; Williams R - relating to original article in Pharmaceutical Research (USA), Mar 1997, vol. 14, pp. 303-308.
- Full Text: false
Evaluation of the proposed FDA pilot-dose response methodology for topical corticosteroid bioequivalence testing
- Demana, Patrick H, Smith, Eric W, Walker, Roderick B, Haigh, John M, Kanfer, Isadore
- Authors: Demana, Patrick H , Smith, Eric W , Walker, Roderick B , Haigh, John M , Kanfer, Isadore
- Date: 1997
- Language: English
- Type: Article
- Identifier: vital:6356 , http://hdl.handle.net/10962/d1006047
- Description: The American FDA has recently released a Guidance document for topical corticosteroid bioequivalence testing. The purpose of this study was to evaluate the recommendations of this document for appropriateness. The new specifications require a dose-vasoconstriction response estimation by the use of a Minolta chromameter in a preliminary pilot study to determine the parameters for use in a pivotal bioequivalence study. Methods. The visually-assessed human skin blanching assay methodology routinely practiced in our laboratories was modified to comply with the requirements of the pilot study so that visual and chromameter data could be compared. Two different cream formulations, each containing 0.12% betamethasone 17-valerate, were used for this comparison. Results. Visual data showed the expected rank order of AUC values for most dose durations whereas the chromameter data did not show similar results. The expected rank order of AUC values for both chromameter and visual data was not observed at very short dose durations. In fitting the data to pharmacodynamic models, equivalent goodness of fit criteria were obtained when several different parameter estimates were used in the model definition, however the visual data were best described by the sigmoid E[subscript max] model while the chromameter data were best described by the simple E[subscript max] model. Conclusions. The E[subscript max] values predicted by the models were close to the observed values for both data sets and, in addition, excellent correlation between the AUC values and the maximum blanching response (R[subscript max]) (r > 0.95) was noted for both methods of assessment. The chromameter ED[subscript 50] values determined in this study were approximately 2 hours for both preparations. At this dose duration the instrument would not be sensitive enough to distinguish between weak blanching responses and normal skin for bioequivalence assessment purposes.
- Full Text: false
- Authors: Demana, Patrick H , Smith, Eric W , Walker, Roderick B , Haigh, John M , Kanfer, Isadore
- Date: 1997
- Language: English
- Type: Article
- Identifier: vital:6356 , http://hdl.handle.net/10962/d1006047
- Description: The American FDA has recently released a Guidance document for topical corticosteroid bioequivalence testing. The purpose of this study was to evaluate the recommendations of this document for appropriateness. The new specifications require a dose-vasoconstriction response estimation by the use of a Minolta chromameter in a preliminary pilot study to determine the parameters for use in a pivotal bioequivalence study. Methods. The visually-assessed human skin blanching assay methodology routinely practiced in our laboratories was modified to comply with the requirements of the pilot study so that visual and chromameter data could be compared. Two different cream formulations, each containing 0.12% betamethasone 17-valerate, were used for this comparison. Results. Visual data showed the expected rank order of AUC values for most dose durations whereas the chromameter data did not show similar results. The expected rank order of AUC values for both chromameter and visual data was not observed at very short dose durations. In fitting the data to pharmacodynamic models, equivalent goodness of fit criteria were obtained when several different parameter estimates were used in the model definition, however the visual data were best described by the sigmoid E[subscript max] model while the chromameter data were best described by the simple E[subscript max] model. Conclusions. The E[subscript max] values predicted by the models were close to the observed values for both data sets and, in addition, excellent correlation between the AUC values and the maximum blanching response (R[subscript max]) (r > 0.95) was noted for both methods of assessment. The chromameter ED[subscript 50] values determined in this study were approximately 2 hours for both preparations. At this dose duration the instrument would not be sensitive enough to distinguish between weak blanching responses and normal skin for bioequivalence assessment purposes.
- Full Text: false
The human skin blanching assay for in vivo topical corticosteroid assessment. II. Subject- and observer-dependent variation in blanching responses
- Haigh, John M, Meyer, Eric, Smith, Eric W, Kanfer, Isadore
- Authors: Haigh, John M , Meyer, Eric , Smith, Eric W , Kanfer, Isadore
- Date: 1997
- Language: English
- Type: text , Article
- Identifier: vital:6382 , http://hdl.handle.net/10962/d1006300
- Description: The human skin blanching (vasoconstriction) assay for the assessment of topical corticosteroids has been in use for over 30 years, the intensity of the drug-induced blanching being assessed subjectively by eye. Both arms of several male and female volunteers are used for product application and more than one observer is used to estimate the degree of induced blanching. There are, therefore, numerous variables which are inherent in the assay procedure. This investigation consisted of three identical trials performed at 8-week intervals, utilising the same 18 volunteers and the same three observers in an attempt to address the question of reproducibility of the assay. From the results obtained it is clear that the assay methodology is capable of consistently distinguishing, on a rank order basis, between preparations which show similar blanching (chemically-equivalent formulations). The similarity of the results for the three individual trials gives considerable confidence to results produced using this methodology. An experiment designed to test the reproducibility of the blanching scores showed that the observers are capable of producing identical results even though visual observation is highly subjective.
- Full Text:
- Authors: Haigh, John M , Meyer, Eric , Smith, Eric W , Kanfer, Isadore
- Date: 1997
- Language: English
- Type: text , Article
- Identifier: vital:6382 , http://hdl.handle.net/10962/d1006300
- Description: The human skin blanching (vasoconstriction) assay for the assessment of topical corticosteroids has been in use for over 30 years, the intensity of the drug-induced blanching being assessed subjectively by eye. Both arms of several male and female volunteers are used for product application and more than one observer is used to estimate the degree of induced blanching. There are, therefore, numerous variables which are inherent in the assay procedure. This investigation consisted of three identical trials performed at 8-week intervals, utilising the same 18 volunteers and the same three observers in an attempt to address the question of reproducibility of the assay. From the results obtained it is clear that the assay methodology is capable of consistently distinguishing, on a rank order basis, between preparations which show similar blanching (chemically-equivalent formulations). The similarity of the results for the three individual trials gives considerable confidence to results produced using this methodology. An experiment designed to test the reproducibility of the blanching scores showed that the observers are capable of producing identical results even though visual observation is highly subjective.
- Full Text:
The human skin-blanching assay for in vitro topical corticosteroid assessment. I. Reproducibility of the assay
- Haigh, John M, Meyer, Eric, Smith, Eric W, Kanfer, Isadore
- Authors: Haigh, John M , Meyer, Eric , Smith, Eric W , Kanfer, Isadore
- Date: 1997
- Language: English
- Type: text , Article
- Identifier: vital:6381 , http://hdl.handle.net/10962/d1006299
- Description: The human skin blanching (vasoconstriction) assay for the assessment of topical corticosteroids has been in use for over 30 years, the intensity of the drug-induced blanching being assessed subjectively by eye. Both arms of several male and female volunteers are used for product application and more than one observer is used to estimate the degree of induced blanching. There are, therefore, numerous variables which are inherent in the assay procedure. This investigation consisted of three identical trials performed at 8-week intervals, utilising the same 18 volunteers and the same three observers in an attempt to address the question of reproducibility of the assay. From the results obtained it is clear that the assay methodology is capable of consistently distinguishing, on a rank order basis, between preparations which show similar blanching (chemically-equivalent formulations). The similarity of the results for the three individual trials gives considerable confidence to results produced using this methodology. An experiment designed to test the reproducibility of the blanching scores showed that the observers are capable of producing identical results even though visual observation is highly subjective.
- Full Text:
- Authors: Haigh, John M , Meyer, Eric , Smith, Eric W , Kanfer, Isadore
- Date: 1997
- Language: English
- Type: text , Article
- Identifier: vital:6381 , http://hdl.handle.net/10962/d1006299
- Description: The human skin blanching (vasoconstriction) assay for the assessment of topical corticosteroids has been in use for over 30 years, the intensity of the drug-induced blanching being assessed subjectively by eye. Both arms of several male and female volunteers are used for product application and more than one observer is used to estimate the degree of induced blanching. There are, therefore, numerous variables which are inherent in the assay procedure. This investigation consisted of three identical trials performed at 8-week intervals, utilising the same 18 volunteers and the same three observers in an attempt to address the question of reproducibility of the assay. From the results obtained it is clear that the assay methodology is capable of consistently distinguishing, on a rank order basis, between preparations which show similar blanching (chemically-equivalent formulations). The similarity of the results for the three individual trials gives considerable confidence to results produced using this methodology. An experiment designed to test the reproducibility of the blanching scores showed that the observers are capable of producing identical results even though visual observation is highly subjective.
- Full Text:
Comparison of the blanching activities of Dermovate, Betnovate and Eumovate creams and ointments
- Meyer, Eric, Magnus, Ashley D, Haigh, John M, Kanfer, Isadore
- Authors: Meyer, Eric , Magnus, Ashley D , Haigh, John M , Kanfer, Isadore
- Date: 1988
- Language: English
- Type: Article
- Identifier: vital:6393 , http://hdl.handle.net/10962/d1006315
- Description: The human skin blanching assay was used to determine the blanching activities of Dermovate, Betnovate and Eumovate creams and ointments. Dermovate was found to elicit a superior blanching response to Betnovate which in turn elicited a superior blanching response to Eumovate, except in the comparison of Betnovate and Eumovate ointments under occlusion. The importance of employing the correct methodology of the blanching assay is emphasized and the good correlation between the results of this study and clinical trials is indicated.
- Full Text: false
- Authors: Meyer, Eric , Magnus, Ashley D , Haigh, John M , Kanfer, Isadore
- Date: 1988
- Language: English
- Type: Article
- Identifier: vital:6393 , http://hdl.handle.net/10962/d1006315
- Description: The human skin blanching assay was used to determine the blanching activities of Dermovate, Betnovate and Eumovate creams and ointments. Dermovate was found to elicit a superior blanching response to Betnovate which in turn elicited a superior blanching response to Eumovate, except in the comparison of Betnovate and Eumovate ointments under occlusion. The importance of employing the correct methodology of the blanching assay is emphasized and the good correlation between the results of this study and clinical trials is indicated.
- Full Text: false
Potency ranking of two new topical corticosteroid creams containing 0.1% desonide or 0.05% halometasone utilizing the human skin-blanching assay
- Meyer, Eric, Smith, Eric W, Haigh, John M, Kanfer, Isadore
- Authors: Meyer, Eric , Smith, Eric W , Haigh, John M , Kanfer, Isadore
- Date: 1988
- Language: English
- Type: Article
- Identifier: vital:6400 , http://hdl.handle.net/10962/d1006327
- Description: The human blanching assay was used to assess the potency of two new proprietary corticosteroid creams. The blanching abilities of 0.1% desonide cream and 0.05% halometasone cream were evaluated relative to the blanching elicited by 0.05% clobetasol 17-propionate cream, 0.1% betamethasone 17-valerate cream and 0.05% clobetasone 17-butyrate cream. The results of the trial indicated that the 0.1% desonide cream falls into the potent group of topical corticosteroid preparations and the 0.05% halomethasone cream falls into the moderately potent group.
- Full Text:
- Authors: Meyer, Eric , Smith, Eric W , Haigh, John M , Kanfer, Isadore
- Date: 1988
- Language: English
- Type: Article
- Identifier: vital:6400 , http://hdl.handle.net/10962/d1006327
- Description: The human blanching assay was used to assess the potency of two new proprietary corticosteroid creams. The blanching abilities of 0.1% desonide cream and 0.05% halometasone cream were evaluated relative to the blanching elicited by 0.05% clobetasol 17-propionate cream, 0.1% betamethasone 17-valerate cream and 0.05% clobetasone 17-butyrate cream. The results of the trial indicated that the 0.1% desonide cream falls into the potent group of topical corticosteroid preparations and the 0.05% halomethasone cream falls into the moderately potent group.
- Full Text:
A stability-indicating liquid chromatographic method for the analysis of erythromycin in stored biological fluids using amperometric detection
- Stubbs, Christopher, Haigh, John M, Kanfer, Isadore
- Authors: Stubbs, Christopher , Haigh, John M , Kanfer, Isadore
- Date: 1987
- Language: English
- Type: Article
- Identifier: vital:6430 , http://hdl.handle.net/10962/d1006592
- Description: A simple, sensitive and reliable high-performance liquid chromatographic procedure has been developed for the determination of erythromycin in human serum and urine using amperometric detection. A solid-phase extraction procedure was used followed by chromatography on a reverse-phase column. The mean recovery of erythromycin from serum and urine was 80%. This method allows both erythromycin and its principle degradation product, anhydroeythromycin, to be determined during a period of sample storage at 4 degree C and minus 15 degree C. The method is sufficiently sensitive and precise and is thus highly suited for use in both pharmacokinetic and stability studies.
- Full Text:
- Authors: Stubbs, Christopher , Haigh, John M , Kanfer, Isadore
- Date: 1987
- Language: English
- Type: Article
- Identifier: vital:6430 , http://hdl.handle.net/10962/d1006592
- Description: A simple, sensitive and reliable high-performance liquid chromatographic procedure has been developed for the determination of erythromycin in human serum and urine using amperometric detection. A solid-phase extraction procedure was used followed by chromatography on a reverse-phase column. The mean recovery of erythromycin from serum and urine was 80%. This method allows both erythromycin and its principle degradation product, anhydroeythromycin, to be determined during a period of sample storage at 4 degree C and minus 15 degree C. The method is sufficiently sensitive and precise and is thus highly suited for use in both pharmacokinetic and stability studies.
- Full Text:
Pharmacokinetics of phenylpropanolamine in humans after a single dose study
- Dowse, Roslind, Haigh, John M, Kanfer, Isadore
- Authors: Dowse, Roslind , Haigh, John M , Kanfer, Isadore
- Date: 1987
- Language: English
- Type: Article
- Identifier: vital:6363 , http://hdl.handle.net/10962/d1006059
- Description: The pharmacokinetics of phenylpropanolamine have been studied in healthy human volunteers following the oral administration of an aqueous solution of the drug (50 mg/200 ml). Blood and urine samples collected throughout the trial were assayed using HPLC with UV detection. The drug was shown to be rapidly absorbed with a mean tmax of 1.47 ± 0.49 h and a mean elimination half-life of 4.0 ± 0.5 h. Phenylpropanolamine is predominantly excreted via the kidney with a mean renal clearance of 0.646 ± 0.089 liter/kg/h and 90.2 ± 1.7% excreted unchanged in the urine. The data were not well described using conventional one or two body compartment models. However, the incorporation of a discontinuous absorption phase into the models resulted in an improved overall fit with better characterisation of the absorption phase.
- Full Text:
- Authors: Dowse, Roslind , Haigh, John M , Kanfer, Isadore
- Date: 1987
- Language: English
- Type: Article
- Identifier: vital:6363 , http://hdl.handle.net/10962/d1006059
- Description: The pharmacokinetics of phenylpropanolamine have been studied in healthy human volunteers following the oral administration of an aqueous solution of the drug (50 mg/200 ml). Blood and urine samples collected throughout the trial were assayed using HPLC with UV detection. The drug was shown to be rapidly absorbed with a mean tmax of 1.47 ± 0.49 h and a mean elimination half-life of 4.0 ± 0.5 h. Phenylpropanolamine is predominantly excreted via the kidney with a mean renal clearance of 0.646 ± 0.089 liter/kg/h and 90.2 ± 1.7% excreted unchanged in the urine. The data were not well described using conventional one or two body compartment models. However, the incorporation of a discontinuous absorption phase into the models resulted in an improved overall fit with better characterisation of the absorption phase.
- Full Text:
High performance liquid chromatographic analysis of oleandomycin in serum and urine
- Stubbs, Christopher, Haigh, John M, Kanfer, Isadore
- Authors: Stubbs, Christopher , Haigh, John M , Kanfer, Isadore
- Date: 1986
- Language: English
- Type: text , Article
- Identifier: vital:6429 , http://hdl.handle.net/10962/d1006590
- Description: The determination of oleandomycin in serum and urine by high-performance liquid chromatography using erythromycin as internal standard is described. The separation was achieved on a reversed-phase C 1 s column employing acetonitrile-0.05 A4 phosphate buffer (30:70), adjusted to pH 7.0, as the mobile phase with UV detection at 200 nm. A solid-phase extraction procedure, combined with a simple phaseseparation step was used prior to chromatographic analysis. Linear calibration curves were obtained in the concentration ranges 0.25-5.0 pg/ml (serum) and 1 .O-25.0 pg/ml (urine). Precise quantitative analysis has been achieved at these levels with relative standard deviations of < 5%.
- Full Text:
- Authors: Stubbs, Christopher , Haigh, John M , Kanfer, Isadore
- Date: 1986
- Language: English
- Type: text , Article
- Identifier: vital:6429 , http://hdl.handle.net/10962/d1006590
- Description: The determination of oleandomycin in serum and urine by high-performance liquid chromatography using erythromycin as internal standard is described. The separation was achieved on a reversed-phase C 1 s column employing acetonitrile-0.05 A4 phosphate buffer (30:70), adjusted to pH 7.0, as the mobile phase with UV detection at 200 nm. A solid-phase extraction procedure, combined with a simple phaseseparation step was used prior to chromatographic analysis. Linear calibration curves were obtained in the concentration ranges 0.25-5.0 pg/ml (serum) and 1 .O-25.0 pg/ml (urine). Precise quantitative analysis has been achieved at these levels with relative standard deviations of < 5%.
- Full Text:
Reply to correspondence: P.M. Gaylarde (1986) The human skin blanching assay—use and abuse
- Haigh, John M, Kanfer, Isadore, Meyer, Eric, Smith, Eric W
- Authors: Haigh, John M , Kanfer, Isadore , Meyer, Eric , Smith, Eric W
- Date: 1986
- Language: English
- Type: Article
- Identifier: vital:6376 , http://hdl.handle.net/10962/d1006293
- Description: Finally, we would like to assure Dr Gaylarde that we do not advocate the use of the human skin blanching assay. There are several other in vivo methods for determining corticosteroid activity which will provide equally meaningful results. What we are advocating is that if the human skin blanching assay is going to be used, then it should be used properly.
- Full Text:
- Authors: Haigh, John M , Kanfer, Isadore , Meyer, Eric , Smith, Eric W
- Date: 1986
- Language: English
- Type: Article
- Identifier: vital:6376 , http://hdl.handle.net/10962/d1006293
- Description: Finally, we would like to assure Dr Gaylarde that we do not advocate the use of the human skin blanching assay. There are several other in vivo methods for determining corticosteroid activity which will provide equally meaningful results. What we are advocating is that if the human skin blanching assay is going to be used, then it should be used properly.
- Full Text:
A stability-indicating HPLC assay with on-line clean-up for betamethasone 17-valerate in topical dosage forms
- Smith, Eric W, Haigh, John M, Kanfer, Isadore
- Authors: Smith, Eric W , Haigh, John M , Kanfer, Isadore
- Date: 1985
- Language: English
- Type: Article
- Identifier: vital:6421 , http://hdl.handle.net/10962/d1006556
- Description: A stability-indicating high-performance liquid chromatographic method with on-line clean-up has been developed for the analysis of betamethasone 17-valerate in topical dosage forms. A short pre-column containing 10 μm octadecylsilane mounted into the sample loop position of an injection valve was used as the primary clean-up step. The utilization of a diode-array UV detector allowed the quantitative analysis of betamethasone 17-valerate together with its degradation product, betamethasone 21-valerate, as well as the qualitative analysis of these compounds, relevant internal standards and the preservatives chlorocresol and methyl hydroxybenzoate contained in the cream and lotion formulations, respectively. Typically, cream and lotion dosage forms were dissolved in acetonitrile and ointments in tetrahydrofuran, internal standards added and aliquots injected onto the analytical system. Dosage form excipients were retained on the loop column and back-flushed to waste with the aid of a second solvent pump while components of interest were allowed to transfer to the analytical column for quantitative analysis. The method is accurate, precise and stability indicating and permits the rapid on-line analysis of betamethasone 17-valerate from complex topical formulation matrices without prior extractions.
- Full Text:
- Authors: Smith, Eric W , Haigh, John M , Kanfer, Isadore
- Date: 1985
- Language: English
- Type: Article
- Identifier: vital:6421 , http://hdl.handle.net/10962/d1006556
- Description: A stability-indicating high-performance liquid chromatographic method with on-line clean-up has been developed for the analysis of betamethasone 17-valerate in topical dosage forms. A short pre-column containing 10 μm octadecylsilane mounted into the sample loop position of an injection valve was used as the primary clean-up step. The utilization of a diode-array UV detector allowed the quantitative analysis of betamethasone 17-valerate together with its degradation product, betamethasone 21-valerate, as well as the qualitative analysis of these compounds, relevant internal standards and the preservatives chlorocresol and methyl hydroxybenzoate contained in the cream and lotion formulations, respectively. Typically, cream and lotion dosage forms were dissolved in acetonitrile and ointments in tetrahydrofuran, internal standards added and aliquots injected onto the analytical system. Dosage form excipients were retained on the loop column and back-flushed to waste with the aid of a second solvent pump while components of interest were allowed to transfer to the analytical column for quantitative analysis. The method is accurate, precise and stability indicating and permits the rapid on-line analysis of betamethasone 17-valerate from complex topical formulation matrices without prior extractions.
- Full Text:
Determination of erythromycin in serum and urine by high performance liquid chromatography with ultraviolet detection
- Stubbs, Christopher, Haigh, John M, Kanfer, Isadore
- Authors: Stubbs, Christopher , Haigh, John M , Kanfer, Isadore
- Date: 1985
- Language: English
- Type: text , Article
- Identifier: vital:6428 , http://hdl.handle.net/10962/d1006576
- Description: A high-performance liquid chromatographic analysis of erythromycin in human serum and urine with UV detection at 200 nm is presented. The method involves a solid-phase extraction procedure followed by a simple phase separation step and chromatography on a reversed-phase column. The method has sensitivity limits of 0.25 and 1.0 g/mL in serum and urine, respectively, and is sufficiently sensitive to monitor concentrations of erythromycin in human serum and urine after the administration of a single 500-mg erythromycin stearate tablet.
- Full Text:
- Authors: Stubbs, Christopher , Haigh, John M , Kanfer, Isadore
- Date: 1985
- Language: English
- Type: text , Article
- Identifier: vital:6428 , http://hdl.handle.net/10962/d1006576
- Description: A high-performance liquid chromatographic analysis of erythromycin in human serum and urine with UV detection at 200 nm is presented. The method involves a solid-phase extraction procedure followed by a simple phase separation step and chromatography on a reversed-phase column. The method has sensitivity limits of 0.25 and 1.0 g/mL in serum and urine, respectively, and is sufficiently sensitive to monitor concentrations of erythromycin in human serum and urine after the administration of a single 500-mg erythromycin stearate tablet.
- Full Text:
Relative potencies of topical corticosteroid formulations
- Haigh, John M, Kanfer, Isadore, Meyer, Eric, Smith, Eric W
- Authors: Haigh, John M , Kanfer, Isadore , Meyer, Eric , Smith, Eric W
- Date: 1985
- Language: English
- Type: Article
- Identifier: vital:6375 , http://hdl.handle.net/10962/d1006291
- Description: It seems to us, and others (Burdick, 1974), that multiple reading times are essential to produce the response-time profile. Comparisons of potencies of topical corticosteroid formulations should only be made on the basis of area under the curve measurements and statistical treatment of all values obtained at each reading time throughout the course of the experiment.
- Full Text:
- Authors: Haigh, John M , Kanfer, Isadore , Meyer, Eric , Smith, Eric W
- Date: 1985
- Language: English
- Type: Article
- Identifier: vital:6375 , http://hdl.handle.net/10962/d1006291
- Description: It seems to us, and others (Burdick, 1974), that multiple reading times are essential to produce the response-time profile. Comparisons of potencies of topical corticosteroid formulations should only be made on the basis of area under the curve measurements and statistical treatment of all values obtained at each reading time throughout the course of the experiment.
- Full Text:
Assessment of topical corticosteroid preparations: the human skin-blanching assay
- Haigh, John M, Kanfer, Isadore
- Authors: Haigh, John M , Kanfer, Isadore
- Date: 1984
- Language: English
- Type: text , Article
- Identifier: vital:6374 , http://hdl.handle.net/10962/d1006284
- Description: (From the introduction) Since the introduction of topical corticosteroid formulations, their use has become widespread, being prescribed for a large variety of dermatological conditions. This widespread use has created a need for a reliable method of assessing the various dosage forms of these compounds. Clinical trials are laborious, costly and difficult to mount as well as being impractical for the screening of large numbers of drugs. Patients suffering from dermatological complaints are not ideal subjects for the testing of topical corticosteroid preparations as it is difficult to obtain standardized lesions which are necessary for the comparison of results between patients (Baker and Sattar, 1968). For these reasons a number of methods have been developed for the screening of novel corticosteroids and testing of topical corticosteroid formulations.
- Full Text:
- Authors: Haigh, John M , Kanfer, Isadore
- Date: 1984
- Language: English
- Type: text , Article
- Identifier: vital:6374 , http://hdl.handle.net/10962/d1006284
- Description: (From the introduction) Since the introduction of topical corticosteroid formulations, their use has become widespread, being prescribed for a large variety of dermatological conditions. This widespread use has created a need for a reliable method of assessing the various dosage forms of these compounds. Clinical trials are laborious, costly and difficult to mount as well as being impractical for the screening of large numbers of drugs. Patients suffering from dermatological complaints are not ideal subjects for the testing of topical corticosteroid preparations as it is difficult to obtain standardized lesions which are necessary for the comparison of results between patients (Baker and Sattar, 1968). For these reasons a number of methods have been developed for the screening of novel corticosteroids and testing of topical corticosteroid formulations.
- Full Text:
Comparative bioavailability of some locally manufactured betamethasone valerate containing preparations
- Meyer, Eric, Haigh, John M, Kanfer, Isadore
- Authors: Meyer, Eric , Haigh, John M , Kanfer, Isadore
- Date: 1983
- Language: English
- Type: Article
- Identifier: vital:6399 , http://hdl.handle.net/10962/d1006326
- Description: The bioavailabilities of three locally manufactured proprietary betamethasone- 17-valerate containing creams and ointments were compared by measuring their abilities to cause blanching of human skin after topical application. The preparations studied were Betnovate Cream and Ointment, Celestoderm-V Cream and Ointment and Persivate Cream and Ointment. Celestoderm-V cream displayed a significantly superior blanching activity over both Betnovate and Persivate creams in' the occluded mode, whereas Persivate cream displayed a significantly superior blanching activity over both Betnovate and Celestoderm-V creams in the unoccluded mode. Persivate ointment was found to produce a significantly superior blanching activity over Betnovate and Celestoderm-V ointments in both the occluded and unoccluded modes of application.
- Full Text:
- Authors: Meyer, Eric , Haigh, John M , Kanfer, Isadore
- Date: 1983
- Language: English
- Type: Article
- Identifier: vital:6399 , http://hdl.handle.net/10962/d1006326
- Description: The bioavailabilities of three locally manufactured proprietary betamethasone- 17-valerate containing creams and ointments were compared by measuring their abilities to cause blanching of human skin after topical application. The preparations studied were Betnovate Cream and Ointment, Celestoderm-V Cream and Ointment and Persivate Cream and Ointment. Celestoderm-V cream displayed a significantly superior blanching activity over both Betnovate and Persivate creams in' the occluded mode, whereas Persivate cream displayed a significantly superior blanching activity over both Betnovate and Celestoderm-V creams in the unoccluded mode. Persivate ointment was found to produce a significantly superior blanching activity over Betnovate and Celestoderm-V ointments in both the occluded and unoccluded modes of application.
- Full Text:
Determination of phenylpropanolamine in serum and urine by high performance liquid chromatography
- Dowse, Roslind, Haigh, John M, Kanfer, Isadore
- Authors: Dowse, Roslind , Haigh, John M , Kanfer, Isadore
- Date: 1983
- Language: English
- Type: Article
- Identifier: vital:6361 , http://hdl.handle.net/10962/d1006056
- Description: A high-performance liquid chromatographic analysis of phenylpropanolamine in human serum and urine without prior derivatization is presented. Using direct UV detection the method is sufficiently sensitive to detect 25 ng of drug/ml of serum or urine; the coefficients of variation at 25 ng/ml and 500 ng/ml were 5.16 and 2.12, respectively, in serum. The method involves serum and urine extraction at a basic pH with chloroform, a single back-extraction, and chromatography on a reverse-phase column. Serum and urine data following administration of a single 150-mg sustained-release tablet of phenylpropanolamine hydrochloride in 6 healthy volunteers demonstrates the suitability of the analytical method.
- Full Text:
- Authors: Dowse, Roslind , Haigh, John M , Kanfer, Isadore
- Date: 1983
- Language: English
- Type: Article
- Identifier: vital:6361 , http://hdl.handle.net/10962/d1006056
- Description: A high-performance liquid chromatographic analysis of phenylpropanolamine in human serum and urine without prior derivatization is presented. Using direct UV detection the method is sufficiently sensitive to detect 25 ng of drug/ml of serum or urine; the coefficients of variation at 25 ng/ml and 500 ng/ml were 5.16 and 2.12, respectively, in serum. The method involves serum and urine extraction at a basic pH with chloroform, a single back-extraction, and chromatography on a reverse-phase column. Serum and urine data following administration of a single 150-mg sustained-release tablet of phenylpropanolamine hydrochloride in 6 healthy volunteers demonstrates the suitability of the analytical method.
- Full Text:
Phenylpropanolamine hydrochloride
- Kanfer, Isadore, Haigh, John M, Dowse, Roslind
- Authors: Kanfer, Isadore , Haigh, John M , Dowse, Roslind
- Date: 1983
- Language: English
- Type: Article
- Identifier: vital:6385 , http://hdl.handle.net/10962/d1006306
- Description: Phenylpropanolamine hydrochloride belongs to the sympathomimetic amine class of drugs and is structurally related to ephedrine hydrochloride. Its synthesis was first reported in 1910 and the first American patent was registered in 1939. The effects of phenylpropanolamine hydrochloride are largely the result of alpha-adrenergic agonist activity resulting from both direct stimulation of adrenergic receptors and release of neuronal norepinephrine. The principal adverse effect of phenylpropanolamine hydrochloride is dose-related hypertension and ventricular arrhythmia has been described. Phenylpropanolamine hydrochloride is widely used as a decongestant and it has been used as an anorectic agent for over 40 years. A report in 1939 described its effect as an hypertensive agent when administered parenterally.
- Full Text:
- Authors: Kanfer, Isadore , Haigh, John M , Dowse, Roslind
- Date: 1983
- Language: English
- Type: Article
- Identifier: vital:6385 , http://hdl.handle.net/10962/d1006306
- Description: Phenylpropanolamine hydrochloride belongs to the sympathomimetic amine class of drugs and is structurally related to ephedrine hydrochloride. Its synthesis was first reported in 1910 and the first American patent was registered in 1939. The effects of phenylpropanolamine hydrochloride are largely the result of alpha-adrenergic agonist activity resulting from both direct stimulation of adrenergic receptors and release of neuronal norepinephrine. The principal adverse effect of phenylpropanolamine hydrochloride is dose-related hypertension and ventricular arrhythmia has been described. Phenylpropanolamine hydrochloride is widely used as a decongestant and it has been used as an anorectic agent for over 40 years. A report in 1939 described its effect as an hypertensive agent when administered parenterally.
- Full Text:
In vitro-in vivo evaluation of a sustained release phenylpropanolamine oral dosage form
- Dowse, Roslind, Haigh, John M, Kanfer, Isadore
- Authors: Dowse, Roslind , Haigh, John M , Kanfer, Isadore
- Date: 1982
- Language: English
- Type: Article
- Identifier: vital:6360 , http://hdl.handle.net/10962/d1006052
- Description: There is increasing interest in measuring pharmacokinetic parameters of phenylpropanolamine (PPA), a sympathomimetic amine used in over-the-counter nasal decongestants and anorectic formulations. A high pressure liquid chromatographic (HPLC) procedure was developed to enable direct ultraviolet detection of PPA, after extraction from serum and urine, without prior derivatization of the drug. This method was used to assay samples obtained from a bioavailability study of BUBtained-releasePPA tablets. The mean serum and urine profiles obtained are presented. The sustained-release tablets were subjected to dissolution testing utilizing the United States Pharmacopoeia (USP XIX) rotating basket method. An internal standard was incorporated into the dissolution fluid to enable direct analysis of the samples by HPLC. A comparison of three different dissolution fluid regimens was carried out to determine if release of the drug was affected by the change in pH of the medium and to select the most convenient method for the final dissolution studies. Some preliminary observations relating to correlations between rate of drug release from the sustained-release dosage form and percent drug absorbed are presented.
- Full Text:
- Authors: Dowse, Roslind , Haigh, John M , Kanfer, Isadore
- Date: 1982
- Language: English
- Type: Article
- Identifier: vital:6360 , http://hdl.handle.net/10962/d1006052
- Description: There is increasing interest in measuring pharmacokinetic parameters of phenylpropanolamine (PPA), a sympathomimetic amine used in over-the-counter nasal decongestants and anorectic formulations. A high pressure liquid chromatographic (HPLC) procedure was developed to enable direct ultraviolet detection of PPA, after extraction from serum and urine, without prior derivatization of the drug. This method was used to assay samples obtained from a bioavailability study of BUBtained-releasePPA tablets. The mean serum and urine profiles obtained are presented. The sustained-release tablets were subjected to dissolution testing utilizing the United States Pharmacopoeia (USP XIX) rotating basket method. An internal standard was incorporated into the dissolution fluid to enable direct analysis of the samples by HPLC. A comparison of three different dissolution fluid regimens was carried out to determine if release of the drug was affected by the change in pH of the medium and to select the most convenient method for the final dissolution studies. Some preliminary observations relating to correlations between rate of drug release from the sustained-release dosage form and percent drug absorbed are presented.
- Full Text:
Comparative blanching activities of some topical corticosteroid containing lotions
- Meyer, I, Kanfer, Isadore, Haigh, John M
- Authors: Meyer, I , Kanfer, Isadore , Haigh, John M
- Date: 1981
- Language: English
- Type: Article
- Identifier: vital:6398 , http://hdl.handle.net/10962/d1006324
- Description: The blanching activities of Betnovate and Celestoderm-V lotions (betamethasone-17-valerate, 0,1%) and Diprosone lotion (betamethasone dipropionate, 0,55%) were determined by measuring their ability to cause blanching of human skin after topical application. Betnovate and Celestoderm-V lotions produced almost identical blanching profiles. Diprosone lotion displayed a statistically significant superior blanching acitivity over both Betnovate and Celestoderm-V lotions over the whole timespan of the trial.
- Full Text:
- Authors: Meyer, I , Kanfer, Isadore , Haigh, John M
- Date: 1981
- Language: English
- Type: Article
- Identifier: vital:6398 , http://hdl.handle.net/10962/d1006324
- Description: The blanching activities of Betnovate and Celestoderm-V lotions (betamethasone-17-valerate, 0,1%) and Diprosone lotion (betamethasone dipropionate, 0,55%) were determined by measuring their ability to cause blanching of human skin after topical application. Betnovate and Celestoderm-V lotions produced almost identical blanching profiles. Diprosone lotion displayed a statistically significant superior blanching acitivity over both Betnovate and Celestoderm-V lotions over the whole timespan of the trial.
- Full Text:
The release of betamethasone 17-valerate from extemporaneous dilutions of a proprietary topical cream
- Magnus, Ashley D, Haigh, John M, Kanfer, Isadore
- Authors: Magnus, Ashley D , Haigh, John M , Kanfer, Isadore
- Date: 1981
- Language: English
- Type: Article
- Identifier: vital:6397 , http://hdl.handle.net/10962/d1006322
- Description: Six different vehicles for topical use were used to prepare 50% dilutions of Betnovate@ (betamethasone 17-valerate, 0.1 %) cream. Blanching assessment was undertaken immediately after preparing the various dilutions and at 1 and 3 months thereafter. Few statistically significant differences were noted between any of the preparations tested indicating that the rate of release of betamethasone 17-valerate is relatively unaffected by dilution. All preparations were assayed by a stability indicating high pressure liquid chromatographic technique for corticosteroid content. A diminution in the content of betamethasone 17-valerate in the E45 dilution was found 14 months after preparation. All other formulations tested were found to comply with label claim specifications.
- Full Text:
- Authors: Magnus, Ashley D , Haigh, John M , Kanfer, Isadore
- Date: 1981
- Language: English
- Type: Article
- Identifier: vital:6397 , http://hdl.handle.net/10962/d1006322
- Description: Six different vehicles for topical use were used to prepare 50% dilutions of Betnovate@ (betamethasone 17-valerate, 0.1 %) cream. Blanching assessment was undertaken immediately after preparing the various dilutions and at 1 and 3 months thereafter. Few statistically significant differences were noted between any of the preparations tested indicating that the rate of release of betamethasone 17-valerate is relatively unaffected by dilution. All preparations were assayed by a stability indicating high pressure liquid chromatographic technique for corticosteroid content. A diminution in the content of betamethasone 17-valerate in the E45 dilution was found 14 months after preparation. All other formulations tested were found to comply with label claim specifications.
- Full Text: