Application of catalysts and nanomaterials in the design of an electrochemical sensor for ochratoxin A
- Authors: Flanagan, Shane Patrick
- Date: 2011 , 2010-12-06
- Subjects: Ochratoxins , Filamentous fungi , Electrochemical sensors , Nanostructured materials , Catalysts , Food contamination
- Language: English
- Type: Thesis , Masters , MSc
- Identifier: vital:4121 , http://hdl.handle.net/10962/d1013328
- Description: Ochratoxin A is the most potent chlorinated derivative of the ochratoxin group, consisting of a 5'-chlorinated dihydroisocoumarin moiety linked by an amide bond to l-phenylalanine. Produced as a secondary fungal metabolite by several species of Aspergillus and Penicillium, ochratoxin A has been shown to readily contaminate a large variety of commodities including cereals, groundnuts, dried fruit, spices and coffee. This has led to widespread contamination of ochratoxin in wine, beer, milk and meat products. As ochratoxin A is a potent nephrotoxin exhibiting teratogenic and carcinogenic properties, the development of a rapid screening platform for the cost effective control of ochratoxin A content in foodstuffs is therefore required. The evaluation of metallophthalocyanine and carbon nanotube electrode modification toward the development of a nanostructured biosensor capable of enhancing the electrochemical detection of ochratoxin A in complex media is presented. Cyclic voltammetry at a glassy carbon electrode allowed for the optimization of detection parameters including pH and type of supporting electrolyte. Britton-Robinson buffer was found to be the most suitable supporting electrolyte in terms of sensitivity and reproducibility obtaining a LOD of 0.28 μM as determined by differential pulse voltammetry. Subsequent analysis determined the dependence of OTA oxidation on pH in acidic media which proceeds with the transfer of two electrons to form a quinone/hydroquinone couple shown to adsorb to the electrode surface. Passivation of the electrode through adsorption of oxidation products was shown to severely limit the detection of OTA upon successive detection cycles. Comparison of various metallophthalocyanine modifiers showed an increase in sensitivity toward the detection of OTA at phthalocyanine complexes with metal based redox processes. However with the exception of NiPc and CoTCPc complexes, phthalocyanine modification was limited by the increase in deviation of current response and extent of fouling. NiPc modification showed an increase in sensitivity by two fold with fouling characteristics comparable to an unmodified electrode while low improvements in fouling was observed at CoTCPc modified electrodes with sensitivity in detection comparable to an unmodified electrode.Modification of the electrode with multi- and single walled carbon nanotubes produced a significant increase in sensitivity toward the detection of ochratoxin A. The electrocatalytic activity of nanotube modifiers was attributed to the increase in surface area and to the addition of oxygenated functional groups upon acid treatment as confirmed by Raman spectroscopy. Acid functionalization of the carbon nanotubes for a period of two hours produced the greatest increase in sensitivity obtaining a respective LOD of 0.09 μM and 0.03 μM for analysis of ochratoxin A at multi- and single walled carbon nanotube modified electrodes. Centrifugal purification of carbon nanotubes was deemed necessary to improve the electrocatalytic activity of the nanotube modifiers through the removal of carbonaceous impurities as visualized by atomic force microscopy. Furthermore, a crude lipase preparation, lipase A, was investigated as a potential biological recognition element for selective detection of ochratoxin A in complex media. Lipase A enabled the hydrolysis of ochratoxin A to the electroactive species ochratoxin α as confirmed by thin layer chromatography and voltammetric analysis. Additional isolation of a pure hydrolase from the lipase A preparation is required prior to utilization within a nanostructured biosensor platform capable of detecting ochratoxin A in complex media.
- Full Text:
- Date Issued: 2011
- Authors: Flanagan, Shane Patrick
- Date: 2011 , 2010-12-06
- Subjects: Ochratoxins , Filamentous fungi , Electrochemical sensors , Nanostructured materials , Catalysts , Food contamination
- Language: English
- Type: Thesis , Masters , MSc
- Identifier: vital:4121 , http://hdl.handle.net/10962/d1013328
- Description: Ochratoxin A is the most potent chlorinated derivative of the ochratoxin group, consisting of a 5'-chlorinated dihydroisocoumarin moiety linked by an amide bond to l-phenylalanine. Produced as a secondary fungal metabolite by several species of Aspergillus and Penicillium, ochratoxin A has been shown to readily contaminate a large variety of commodities including cereals, groundnuts, dried fruit, spices and coffee. This has led to widespread contamination of ochratoxin in wine, beer, milk and meat products. As ochratoxin A is a potent nephrotoxin exhibiting teratogenic and carcinogenic properties, the development of a rapid screening platform for the cost effective control of ochratoxin A content in foodstuffs is therefore required. The evaluation of metallophthalocyanine and carbon nanotube electrode modification toward the development of a nanostructured biosensor capable of enhancing the electrochemical detection of ochratoxin A in complex media is presented. Cyclic voltammetry at a glassy carbon electrode allowed for the optimization of detection parameters including pH and type of supporting electrolyte. Britton-Robinson buffer was found to be the most suitable supporting electrolyte in terms of sensitivity and reproducibility obtaining a LOD of 0.28 μM as determined by differential pulse voltammetry. Subsequent analysis determined the dependence of OTA oxidation on pH in acidic media which proceeds with the transfer of two electrons to form a quinone/hydroquinone couple shown to adsorb to the electrode surface. Passivation of the electrode through adsorption of oxidation products was shown to severely limit the detection of OTA upon successive detection cycles. Comparison of various metallophthalocyanine modifiers showed an increase in sensitivity toward the detection of OTA at phthalocyanine complexes with metal based redox processes. However with the exception of NiPc and CoTCPc complexes, phthalocyanine modification was limited by the increase in deviation of current response and extent of fouling. NiPc modification showed an increase in sensitivity by two fold with fouling characteristics comparable to an unmodified electrode while low improvements in fouling was observed at CoTCPc modified electrodes with sensitivity in detection comparable to an unmodified electrode.Modification of the electrode with multi- and single walled carbon nanotubes produced a significant increase in sensitivity toward the detection of ochratoxin A. The electrocatalytic activity of nanotube modifiers was attributed to the increase in surface area and to the addition of oxygenated functional groups upon acid treatment as confirmed by Raman spectroscopy. Acid functionalization of the carbon nanotubes for a period of two hours produced the greatest increase in sensitivity obtaining a respective LOD of 0.09 μM and 0.03 μM for analysis of ochratoxin A at multi- and single walled carbon nanotube modified electrodes. Centrifugal purification of carbon nanotubes was deemed necessary to improve the electrocatalytic activity of the nanotube modifiers through the removal of carbonaceous impurities as visualized by atomic force microscopy. Furthermore, a crude lipase preparation, lipase A, was investigated as a potential biological recognition element for selective detection of ochratoxin A in complex media. Lipase A enabled the hydrolysis of ochratoxin A to the electroactive species ochratoxin α as confirmed by thin layer chromatography and voltammetric analysis. Additional isolation of a pure hydrolase from the lipase A preparation is required prior to utilization within a nanostructured biosensor platform capable of detecting ochratoxin A in complex media.
- Full Text:
- Date Issued: 2011
Nanomaterial modified electrodes : optimization of voltammetric sensors for pharmaceutical and industrial application
- Authors: Brimecombe, Rory Dennis
- Date: 2011
- Subjects: Voltammetry , Electrochemistry , Nanotubes , Nanostructured materials
- Language: English
- Type: Thesis , Doctoral , PhD
- Identifier: vital:4101 , http://hdl.handle.net/10962/d1009721
- Description: Nanomaterials, in particular carbon nanotubes have been shown to exhibit favourable properties for the enhancement of electrochemical detection of target analytes in complex matrices. There is however scope for improvement in terms of the optimization thereof in electrochemical sensors surface modification. The aim of this thesis was to examine methods that would result in increased current response, lowered passivation and application of such modified surfaces with application to pharmaceutically and industrially relevant analytes. Current methods for enhancing the performance of carbon nanotubes include acid functionalization which not only increases the hydrophilicity of the nanotubes, and consequently their ability to provide stable (aqueous) suspensions, but also introduces electrochemically active sites. This particular approach is however not normalized in the literature. Over-exposure to acid treatment results in loss of structural integrity of the carbon nanotubes, and as such a fine balance exists between achieving these dual outcomes. Guided by high resolution scanning electron microscopy, atomic force microscopy, voltammetric and impedance studies, this thesis examined the role of the length of time of the acid functionalization process as well as the impact of activation of carbon nanotubes and fullerenes on electrochemical sensor performance. Based on desired charge transfer resistances, rate transfer coefficients and sensitivity towards redox probes the optimal length of acid functionalization for multiwalled carbon nanotubes was 9 hours and 4 hours for single-walled carbon nanotubes. Further improvements in the desired outcomes were achieved through electrochemical activation of the modified electrode surface by cycling in the presence of catechol, in a novel approach. By employing electrochemical impedance spectroscopy it was observed that catechol activation resulted in lowered charge transfer resistance, before and after activation, with functionalized multi-walled carbon nanotubes (9 hours) exhibiting the greatest decrease of 90 % and functionalized single-walled carbon nanotubes (4 hours), a 50 % decrease. Corresponding increases in the heterologous rate transfer coefficient showed a 770 % increase for functionalized multi-walled carbon nanotubes (9 hours), following catechol activation. Comparative observations for fullerenes following partial reduction in potassium hydroxide yielded a 30 % decrease in charge transfer resistance, with an increased heterologous rate transfer coefficient at a fullerene modified surface The performance of the nanomaterial modified electrodes was applied to the detection of wortmannin with applications in bioprocess control and in the pharmaceutical sector as well as to the detection and monitoring of the industrial dye Reactive red. Of particular relevance to these analytes was the assessment of the nanomaterial modified electrodes for enhanced stability, reproducibility, sensitivity and decreased passivation effects. In this study the first known account of wortmannin detection through electrochemical methods is reported. Voltammetric characterization of wortmannin revealed an irreversible cathodic process with a total number of 4 electrons and a diffusion coefficient of 1.19 x 10-7 cm².s⁻¹. At a functionalized multiwalled carbon nanotubes modified glassy carbon electrode a limit of detection of 0.128 nmol.cm⁻³ was obtained, and with limited surface passivation the detection scheme afforded pertinent analyses in biological media representing a substantial improvement over chromatographic detection methods. This study also provided the first account of the voltammetric detection of reactive red, competing favourably with traditional spectroscopic methods for monitoring biodegradation of this compound in real time.
- Full Text:
- Date Issued: 2011
- Authors: Brimecombe, Rory Dennis
- Date: 2011
- Subjects: Voltammetry , Electrochemistry , Nanotubes , Nanostructured materials
- Language: English
- Type: Thesis , Doctoral , PhD
- Identifier: vital:4101 , http://hdl.handle.net/10962/d1009721
- Description: Nanomaterials, in particular carbon nanotubes have been shown to exhibit favourable properties for the enhancement of electrochemical detection of target analytes in complex matrices. There is however scope for improvement in terms of the optimization thereof in electrochemical sensors surface modification. The aim of this thesis was to examine methods that would result in increased current response, lowered passivation and application of such modified surfaces with application to pharmaceutically and industrially relevant analytes. Current methods for enhancing the performance of carbon nanotubes include acid functionalization which not only increases the hydrophilicity of the nanotubes, and consequently their ability to provide stable (aqueous) suspensions, but also introduces electrochemically active sites. This particular approach is however not normalized in the literature. Over-exposure to acid treatment results in loss of structural integrity of the carbon nanotubes, and as such a fine balance exists between achieving these dual outcomes. Guided by high resolution scanning electron microscopy, atomic force microscopy, voltammetric and impedance studies, this thesis examined the role of the length of time of the acid functionalization process as well as the impact of activation of carbon nanotubes and fullerenes on electrochemical sensor performance. Based on desired charge transfer resistances, rate transfer coefficients and sensitivity towards redox probes the optimal length of acid functionalization for multiwalled carbon nanotubes was 9 hours and 4 hours for single-walled carbon nanotubes. Further improvements in the desired outcomes were achieved through electrochemical activation of the modified electrode surface by cycling in the presence of catechol, in a novel approach. By employing electrochemical impedance spectroscopy it was observed that catechol activation resulted in lowered charge transfer resistance, before and after activation, with functionalized multi-walled carbon nanotubes (9 hours) exhibiting the greatest decrease of 90 % and functionalized single-walled carbon nanotubes (4 hours), a 50 % decrease. Corresponding increases in the heterologous rate transfer coefficient showed a 770 % increase for functionalized multi-walled carbon nanotubes (9 hours), following catechol activation. Comparative observations for fullerenes following partial reduction in potassium hydroxide yielded a 30 % decrease in charge transfer resistance, with an increased heterologous rate transfer coefficient at a fullerene modified surface The performance of the nanomaterial modified electrodes was applied to the detection of wortmannin with applications in bioprocess control and in the pharmaceutical sector as well as to the detection and monitoring of the industrial dye Reactive red. Of particular relevance to these analytes was the assessment of the nanomaterial modified electrodes for enhanced stability, reproducibility, sensitivity and decreased passivation effects. In this study the first known account of wortmannin detection through electrochemical methods is reported. Voltammetric characterization of wortmannin revealed an irreversible cathodic process with a total number of 4 electrons and a diffusion coefficient of 1.19 x 10-7 cm².s⁻¹. At a functionalized multiwalled carbon nanotubes modified glassy carbon electrode a limit of detection of 0.128 nmol.cm⁻³ was obtained, and with limited surface passivation the detection scheme afforded pertinent analyses in biological media representing a substantial improvement over chromatographic detection methods. This study also provided the first account of the voltammetric detection of reactive red, competing favourably with traditional spectroscopic methods for monitoring biodegradation of this compound in real time.
- Full Text:
- Date Issued: 2011
Nanostructures and metallophthalocyanines : applications in microbial fuel cells
- Authors: Edwards, Sean
- Date: 2011
- Subjects: Microbial fuel cells , Waste products as fuel , Nanostructured materials , Electrochemistry , Nanotubes
- Language: English
- Type: Thesis , Masters , MSc
- Identifier: vital:4107 , http://hdl.handle.net/10962/d1011742 , Microbial fuel cells , Waste products as fuel , Nanostructured materials , Electrochemistry , Nanotubes
- Description: Microbial fuel cells (MFCs) are a promising form of alternative energy capable of harnessing the potential energy stores in organic waste. The oxygen reduction reaction (ORR) forms an integral role in the generation of electricity in MFCs however it is also a potential obstacle in enhancing the performance of MFCs. Platinum, a commonly used catalyst for the ORR, is expensive and rare. Significant research has been conducted into developing alternative catalysts. Metallophthalocyanines (MPc) have garnered attention for use as catalysts. Iron phthalocyanine (FePc) has been shown to have catalytic activity towards the reduction of oxygen. Coupling of the catalyst to nanostructured carbon materials, such as multi-walled carbon nanotubes, has been observed to have several advantages as nanostructures have a high surface-to-volume ratio. In this study, we have attempted to assess the suitability of FePc, both its bulk and nanostructured form, as an oxygen reduction catalyst and acid functionalized multi-walled carbon nanotubes for use as a catalyst support using electrochemical techniques such as cyclic voltammetry and electrochemical impedance spectroscopy. We showed, for the first time, the catalytic nature of nanostructured FePc towards the ORR. Applying the data obtained from the electrochemical analyses, electrodes were modified using FePc and MWCNTs and applied to an Enterobacter cloacae-based MFC. Several operational parameters of the MFC, such as temperature and ionic strength, were optimized during the course of the study. We showed that optimized FePc:MWCNT-modified electrodes compared favourably to platinum-based electrodes in terms of power densities obtained in a microbial fuel cell.
- Full Text:
- Date Issued: 2011
- Authors: Edwards, Sean
- Date: 2011
- Subjects: Microbial fuel cells , Waste products as fuel , Nanostructured materials , Electrochemistry , Nanotubes
- Language: English
- Type: Thesis , Masters , MSc
- Identifier: vital:4107 , http://hdl.handle.net/10962/d1011742 , Microbial fuel cells , Waste products as fuel , Nanostructured materials , Electrochemistry , Nanotubes
- Description: Microbial fuel cells (MFCs) are a promising form of alternative energy capable of harnessing the potential energy stores in organic waste. The oxygen reduction reaction (ORR) forms an integral role in the generation of electricity in MFCs however it is also a potential obstacle in enhancing the performance of MFCs. Platinum, a commonly used catalyst for the ORR, is expensive and rare. Significant research has been conducted into developing alternative catalysts. Metallophthalocyanines (MPc) have garnered attention for use as catalysts. Iron phthalocyanine (FePc) has been shown to have catalytic activity towards the reduction of oxygen. Coupling of the catalyst to nanostructured carbon materials, such as multi-walled carbon nanotubes, has been observed to have several advantages as nanostructures have a high surface-to-volume ratio. In this study, we have attempted to assess the suitability of FePc, both its bulk and nanostructured form, as an oxygen reduction catalyst and acid functionalized multi-walled carbon nanotubes for use as a catalyst support using electrochemical techniques such as cyclic voltammetry and electrochemical impedance spectroscopy. We showed, for the first time, the catalytic nature of nanostructured FePc towards the ORR. Applying the data obtained from the electrochemical analyses, electrodes were modified using FePc and MWCNTs and applied to an Enterobacter cloacae-based MFC. Several operational parameters of the MFC, such as temperature and ionic strength, were optimized during the course of the study. We showed that optimized FePc:MWCNT-modified electrodes compared favourably to platinum-based electrodes in terms of power densities obtained in a microbial fuel cell.
- Full Text:
- Date Issued: 2011
Probing the biocompatibility of biomedical interfaces using the Quartz Crystal Microbalance with Dissipation
- Authors: Cromhout, Mary
- Date: 2011
- Subjects: Biomedical materials , Nanostructured materials , Biomedical engineering , Quartz crystal microbalances , Blood proteins , Nanoparticles
- Language: English
- Type: Thesis , Masters , MSc
- Identifier: vital:4102 , http://hdl.handle.net/10962/d1010660
- Description: The biomedical application of nanotechnology has come into the spotlight, with the promise of ‘personalised’ therapeutics that couple early diagnosis with targeted therapeutic activity. Due to the rapid growth of the biomedical applications of nanoparticles, along with the lack of understanding concerning their interactions with biomolecules, there is a pressing need for the development of standard methods directed at investigating the effect of introducing these unique particles into the human body. The central aim of this research is to establish a platform directed at assessing the biological fate of pioneering therapeutic particulate agents, such as metallophthalocyanines (MPcs) and multi-walled carbon nanotubes (FMWCNTs). In particular, we proposed, that Quartz Crystal Microbalance with Dissipation (QCM-D) technology may be employed to assess the composition of blood protein corona deposited on the therapeutic surface, and subsequently assess the biocompatibility of such particles. The proposed method of protein detection utilises the nanogram sensitivity of QCM-D technology to monitor highly specific antibody-antigen interactions. In particular those interactions which occur when probe antibodies are used to detect adsorbed blood proteins deposited on target particle-modified sensor surfaces. Protein detection analysis was directed toward identification of surface bound human serum albumin, complement factor C3c, and human plasma fibrinogen. Preliminary analysis of generic biomedical surfaces indicated human serum albumin demonstrates a higher binding affinity towards positively charged surfaces (i.e. cysteamine self-assembled monolayer), followed by hydrophobic surfaces. Detection of complement C3c, corresponded with literature, where lower levels were detected on negatively charged surfaces (i.e. mercapto undecanoic acid self-assembled monolayer), and higher levels of more hydrophobic surfaces (i.e. 11-amino undecane thiol self-assembled monolayer). Human plasma fibrinogen was observed to favour hydrophilic over hydrophobic self-assembled monolayer surfaces, which was in accordance with literature. Application of the proposed protein detection method for biocompatibility analysis of target therapeutic molecules, namely metallophthalocyanines and acid functionalised multi-walled carbon nanotubes, demonstrated a dependence on modified-surface film characteristics, such as surface charge and topography with regards to human serum albumin and human plasma fibrinogen analysis representing new insights into their potential biomolecular interactions The highest levels of detected human serum albumin and complement C3c were detected on the GePcSmix-modified surfaces. AlPcSmix-modified surfaces analysis suggested the highest levels of human plasma fibrinogen. Two methods of acid functionalisation were employed, using both nitric and sulphuric acid, and pure nitric acid. A general increase in detected human serum albumin, corresponding with an increase in functionalisation time, was observed. Complement C3c detection suggested an increase in deposited complement C3c, with increasing functionalisation time, when assessing nitric acid functionalised multi-walled carbon nanotubes, and a decrease, with increasing functionalisation time, when assessing nitric and sulphuric acid functionalised multi-walled carbon nanotubes. Analysis of human plasma fibrinogen was inconclusive, as were cytotoxicity experiments utilising MCF-7 cells in the presence of metallophthalocyanine complexes, raising simultaneously important considerations for their application and study. In the first such detailed examination of its kind it was concluded that the proposed method of protein detection, using QCM-D, allows for the rudimentary but rapid means of analysis of select protein corona deposited on particulate biomedical surfaces.
- Full Text:
- Date Issued: 2011
- Authors: Cromhout, Mary
- Date: 2011
- Subjects: Biomedical materials , Nanostructured materials , Biomedical engineering , Quartz crystal microbalances , Blood proteins , Nanoparticles
- Language: English
- Type: Thesis , Masters , MSc
- Identifier: vital:4102 , http://hdl.handle.net/10962/d1010660
- Description: The biomedical application of nanotechnology has come into the spotlight, with the promise of ‘personalised’ therapeutics that couple early diagnosis with targeted therapeutic activity. Due to the rapid growth of the biomedical applications of nanoparticles, along with the lack of understanding concerning their interactions with biomolecules, there is a pressing need for the development of standard methods directed at investigating the effect of introducing these unique particles into the human body. The central aim of this research is to establish a platform directed at assessing the biological fate of pioneering therapeutic particulate agents, such as metallophthalocyanines (MPcs) and multi-walled carbon nanotubes (FMWCNTs). In particular, we proposed, that Quartz Crystal Microbalance with Dissipation (QCM-D) technology may be employed to assess the composition of blood protein corona deposited on the therapeutic surface, and subsequently assess the biocompatibility of such particles. The proposed method of protein detection utilises the nanogram sensitivity of QCM-D technology to monitor highly specific antibody-antigen interactions. In particular those interactions which occur when probe antibodies are used to detect adsorbed blood proteins deposited on target particle-modified sensor surfaces. Protein detection analysis was directed toward identification of surface bound human serum albumin, complement factor C3c, and human plasma fibrinogen. Preliminary analysis of generic biomedical surfaces indicated human serum albumin demonstrates a higher binding affinity towards positively charged surfaces (i.e. cysteamine self-assembled monolayer), followed by hydrophobic surfaces. Detection of complement C3c, corresponded with literature, where lower levels were detected on negatively charged surfaces (i.e. mercapto undecanoic acid self-assembled monolayer), and higher levels of more hydrophobic surfaces (i.e. 11-amino undecane thiol self-assembled monolayer). Human plasma fibrinogen was observed to favour hydrophilic over hydrophobic self-assembled monolayer surfaces, which was in accordance with literature. Application of the proposed protein detection method for biocompatibility analysis of target therapeutic molecules, namely metallophthalocyanines and acid functionalised multi-walled carbon nanotubes, demonstrated a dependence on modified-surface film characteristics, such as surface charge and topography with regards to human serum albumin and human plasma fibrinogen analysis representing new insights into their potential biomolecular interactions The highest levels of detected human serum albumin and complement C3c were detected on the GePcSmix-modified surfaces. AlPcSmix-modified surfaces analysis suggested the highest levels of human plasma fibrinogen. Two methods of acid functionalisation were employed, using both nitric and sulphuric acid, and pure nitric acid. A general increase in detected human serum albumin, corresponding with an increase in functionalisation time, was observed. Complement C3c detection suggested an increase in deposited complement C3c, with increasing functionalisation time, when assessing nitric acid functionalised multi-walled carbon nanotubes, and a decrease, with increasing functionalisation time, when assessing nitric and sulphuric acid functionalised multi-walled carbon nanotubes. Analysis of human plasma fibrinogen was inconclusive, as were cytotoxicity experiments utilising MCF-7 cells in the presence of metallophthalocyanine complexes, raising simultaneously important considerations for their application and study. In the first such detailed examination of its kind it was concluded that the proposed method of protein detection, using QCM-D, allows for the rudimentary but rapid means of analysis of select protein corona deposited on particulate biomedical surfaces.
- Full Text:
- Date Issued: 2011
- «
- ‹
- 1
- ›
- »