- Title
- The influence of dose on the kinetic parameters and dosimetric features of the main thermoluminescence glow peak in α-Al2O3: C, Mg
- Creator
- Kalita, Jitumani M, Chithambo, Makaiko L
- Date
- 2017
- Type
- text
- Type
- article
- Identifier
- http://hdl.handle.net/10962/119834
- Identifier
- vital:34787
- Identifier
- https://doi.org/10.1016/j.nimb.2016.12.027
- Description
- The influence of dose (0.1–100 Gy) on the kinetic parameters and the dosimetric features of the main glow peak of α-Al2O3:C,Mg have been investigated. Thermoluminescence (TL) measured at 1 °C/s shows a very high intensity glow peak at 161 °C and six secondary peaks at 42, 72, 193, 279, 330, 370 °C respectively. Analysis shows that the main peak follows first order kinetics irrespective of the irradiation dose. The activation energy is found to be consistent at 1.37 eV and the frequency factor is of the order of 1014 s−1 for any dose between 0.1 and 100 Gy. Further, the analysis for thermal quenching of the main peak of 0.1 Gy irradiated sample shows that the activation energy for thermal quenching is (0.94 ± 0.04) eV.
- Format
- 8 pages, pdf
- Language
- English
- Relation
- Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, Kalita, J.M. and Chithambo, M.L., 2017. The influence of dose on the kinetic parameters and dosimetric features of the main thermoluminescence glow peak in α-Al2O3: C, Mg. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 394, pp.12-19., Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms volume 394 12 19 March 2017 0168-583X
- Rights
- Elsevier
- Rights
- Use of this resource is governed by the terms and conditions of the Science Direct Terms and Conditions Statement (https://www.elsevier.com/legal/elsevier-website-terms-and-conditions)
- Hits: 1331
- Visitors: 1467
- Downloads: 156
Thumbnail | File | Description | Size | Format | |||
---|---|---|---|---|---|---|---|
View Details | SOURCE1 | The influence of dose on the kinetic parameters and dosimetric features of the main thermoluminescence glow peak in α-Al2O3.jpg | 38 KB | JPEG Image | View Details |