Description and identification of white grubs (Coleoptera: Scarabaeidae) attacking pineapple crops in South Africa
- Smith, Tamara J, Petty, G, Villet, Martin H
- Authors: Smith, Tamara J , Petty, G , Villet, Martin H
- Date: 1995
- Language: English
- Type: text , Article
- Identifier: vital:6853 , http://hdl.handle.net/10962/d1011134
- Description: Larvae of five species of scarabaeid beetles, Asthenopholis subfasciata Blanchard, Trochalus politus Moser, Macrophylla ciliata Herbst, Congela valida Peringuey and Adoretus ictericus Burmeister, and adults of a sixth species, Heteronychus arator (Fabricius), cause considerable economic damage to the root systems of pineapple plants. The biologies of the species differ, making reliable identification essential. Since no convenient method is available to identify them, both field and laboratory keys are provided for the identification of third instar larvae of the six species, and detailed, illustrated descriptions for confirming their identifications
- Full Text:
- Authors: Smith, Tamara J , Petty, G , Villet, Martin H
- Date: 1995
- Language: English
- Type: text , Article
- Identifier: vital:6853 , http://hdl.handle.net/10962/d1011134
- Description: Larvae of five species of scarabaeid beetles, Asthenopholis subfasciata Blanchard, Trochalus politus Moser, Macrophylla ciliata Herbst, Congela valida Peringuey and Adoretus ictericus Burmeister, and adults of a sixth species, Heteronychus arator (Fabricius), cause considerable economic damage to the root systems of pineapple plants. The biologies of the species differ, making reliable identification essential. Since no convenient method is available to identify them, both field and laboratory keys are provided for the identification of third instar larvae of the six species, and detailed, illustrated descriptions for confirming their identifications
- Full Text:
Sensitive high-performance liquid chromatographic determination of cyclizine and its demethylated metabolite, norcyclizine, in biological fluids using coulometric detection
- Walker, Roderick B, Kanfer, Isadore
- Authors: Walker, Roderick B , Kanfer, Isadore
- Date: 1995
- Language: English
- Type: text , Article
- Identifier: vital:6452 , http://hdl.handle.net/10962/d1006640 , http://dx.doi.org/10.1016/0378-4347(95)00202-T
- Description: An accurate, sensitive, selective and reproducible high-performance liquid chromatographic method with coulometric detection for the determination of cyclizine and its inactive demethylated metabolite, norcyclizine, in biological fluids has been developed. The drugs were separated using a custom packed reversed-phase C18 analytical column and phosphate buffer (0.05 M, pH 3)-acetonitrile (7:3) as mobile phase. The dual electrode coulometric detector was operated in the "oxidative-screen" mode with the upstream electrode (detector 1) set at 0.55 V and the downstream electrode (detector 2) set at 0.90 V. Serum and urine samples were prepared for analysis by solid-phase extraction, followed by a simple phase-separation step. The limit of quantitation was 1 ng/ml for both cyclizine and norcyclizine in serum and urine.
- Full Text:
- Authors: Walker, Roderick B , Kanfer, Isadore
- Date: 1995
- Language: English
- Type: text , Article
- Identifier: vital:6452 , http://hdl.handle.net/10962/d1006640 , http://dx.doi.org/10.1016/0378-4347(95)00202-T
- Description: An accurate, sensitive, selective and reproducible high-performance liquid chromatographic method with coulometric detection for the determination of cyclizine and its inactive demethylated metabolite, norcyclizine, in biological fluids has been developed. The drugs were separated using a custom packed reversed-phase C18 analytical column and phosphate buffer (0.05 M, pH 3)-acetonitrile (7:3) as mobile phase. The dual electrode coulometric detector was operated in the "oxidative-screen" mode with the upstream electrode (detector 1) set at 0.55 V and the downstream electrode (detector 2) set at 0.90 V. Serum and urine samples were prepared for analysis by solid-phase extraction, followed by a simple phase-separation step. The limit of quantitation was 1 ng/ml for both cyclizine and norcyclizine in serum and urine.
- Full Text:
The effects of elevated and ambient temperature conditions on dilutions of fluocinolone acetonide ointment assessed using the human skin-blanching assay
- Haigh, John M, Smith, Eric W
- Authors: Haigh, John M , Smith, Eric W
- Date: 1995
- Language: English
- Type: text , Article
- Identifier: vital:6380 , http://hdl.handle.net/10962/d1006298
- Description: Topical corticosteroid formulations have been in use now for some 30 years and many methods are available for the in vivo assessment of these preparations. Of all the assays described in the literature, the one first advocated by McKenzie and Stoughton, the so-called vasoconstrictor assay, is one of the most reliable if performed by experienced researchers using - the optimised methodology. Topical application of corticosteroids produces a whitening (blanching) of the skin, the intensity of which is directly proportional to the clinical efficacy of the formulation. Assessment of the degree of blanching produced is therefore of use in determining the rate and extent of corticosteroid release' from the semi-solid base through the stratum corneum. Since it is the degree of blanching which is measured, we prefer to call this test the human skin blanching assay. Some of the main advantages of this assay technique are that normal healthy skin is used therefore persons with dermatological complaints are not compromised, it is not painful for the volunteers, it is non-invasive and several formulations can be evaluated simultaneously. Most commercially available topical corticosteroid preparations have been formulated in such a way as to provide optimum release of the active ingredient from the base through the stratum corneum. Despite this fact, many practitioners often prescribe dilutions of topical corticosteroid formulations, presumably in an effort to reduce the unwanted side effects. This could be problematic; dilution with an incompatible base could destroy the delivery environment thus considerably reducing the efficacy of the formulation. The method of dilution could also play a role in the suitability of the final preparation. The objective of this work was to determine the effects of two different dilutions of fluocinolone ointment at both ambient and elevated temperature on the blanching produced by the dilutions and, by inference, the relative clinical efficacies of these dilutions compared to the full strength product.
- Full Text:
- Authors: Haigh, John M , Smith, Eric W
- Date: 1995
- Language: English
- Type: text , Article
- Identifier: vital:6380 , http://hdl.handle.net/10962/d1006298
- Description: Topical corticosteroid formulations have been in use now for some 30 years and many methods are available for the in vivo assessment of these preparations. Of all the assays described in the literature, the one first advocated by McKenzie and Stoughton, the so-called vasoconstrictor assay, is one of the most reliable if performed by experienced researchers using - the optimised methodology. Topical application of corticosteroids produces a whitening (blanching) of the skin, the intensity of which is directly proportional to the clinical efficacy of the formulation. Assessment of the degree of blanching produced is therefore of use in determining the rate and extent of corticosteroid release' from the semi-solid base through the stratum corneum. Since it is the degree of blanching which is measured, we prefer to call this test the human skin blanching assay. Some of the main advantages of this assay technique are that normal healthy skin is used therefore persons with dermatological complaints are not compromised, it is not painful for the volunteers, it is non-invasive and several formulations can be evaluated simultaneously. Most commercially available topical corticosteroid preparations have been formulated in such a way as to provide optimum release of the active ingredient from the base through the stratum corneum. Despite this fact, many practitioners often prescribe dilutions of topical corticosteroid formulations, presumably in an effort to reduce the unwanted side effects. This could be problematic; dilution with an incompatible base could destroy the delivery environment thus considerably reducing the efficacy of the formulation. The method of dilution could also play a role in the suitability of the final preparation. The objective of this work was to determine the effects of two different dilutions of fluocinolone ointment at both ambient and elevated temperature on the blanching produced by the dilutions and, by inference, the relative clinical efficacies of these dilutions compared to the full strength product.
- Full Text:
- «
- ‹
- 1
- ›
- »