Simultaneous voltammetric determination of dopamine and serotonin on carbon paste electrodes modified with iron (II) phthalocyanine complexes
- Oni, Joshua, Nyokong, Tebello
- Authors: Oni, Joshua , Nyokong, Tebello
- Date: 2001
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/291603 , vital:56891 , xlink:href="https://doi.org/10.1016/S0003-2670(01)00822-4"
- Description: Carbon paste electrodes (CPE) containing iron(II) phthalocyanine (FePc) and iron(II) tetrasulfophthalocyanine ([FeTSPc]4−) were used for the detection of dopamine (DA) and serotonin (5-HT). Both complexes showed catalytic activity towards the detection of DA and 5-HT. The catalytic activities of [FeTSPc]4− and FePc are compared with those of [CoTSPc]4−, [NiTSPc] 4−, CoPc and NiPc complexes and with those of metal(II) tetraaminophthalocyanines (MTAPc, where M=Ni, Co or Fe) complexes. A significant improvement in the reversibility of the DA oxidation couple was observed on [FeTSPc]4− and FePc modified CPE. [FeTSPc]4− and other [MTSPc]4− modified electrodes inhibited the detection of ascorbic acid (AA), a major interferent in the detection of DA. Simultaneous detection of DA and 5-HT on [FeTSPc]4− modified CPE, in the presence of AA, showed that AA does not interfere with the determination of both species. Also no interference between DA and 5-HT was observed.
- Full Text:
- Date Issued: 2001
- Authors: Oni, Joshua , Nyokong, Tebello
- Date: 2001
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/291603 , vital:56891 , xlink:href="https://doi.org/10.1016/S0003-2670(01)00822-4"
- Description: Carbon paste electrodes (CPE) containing iron(II) phthalocyanine (FePc) and iron(II) tetrasulfophthalocyanine ([FeTSPc]4−) were used for the detection of dopamine (DA) and serotonin (5-HT). Both complexes showed catalytic activity towards the detection of DA and 5-HT. The catalytic activities of [FeTSPc]4− and FePc are compared with those of [CoTSPc]4−, [NiTSPc] 4−, CoPc and NiPc complexes and with those of metal(II) tetraaminophthalocyanines (MTAPc, where M=Ni, Co or Fe) complexes. A significant improvement in the reversibility of the DA oxidation couple was observed on [FeTSPc]4− and FePc modified CPE. [FeTSPc]4− and other [MTSPc]4− modified electrodes inhibited the detection of ascorbic acid (AA), a major interferent in the detection of DA. Simultaneous detection of DA and 5-HT on [FeTSPc]4− modified CPE, in the presence of AA, showed that AA does not interfere with the determination of both species. Also no interference between DA and 5-HT was observed.
- Full Text:
- Date Issued: 2001
Construction and characterization of carbon paste ultra-microelectrodes
- Oni, Joshua, Westbroek, Philippe, Nyokong, Tebello
- Authors: Oni, Joshua , Westbroek, Philippe , Nyokong, Tebello
- Date: 2001
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/291531 , vital:56884 , xlink:href="https://doi.org/10.1016/S1388-2481(01)00212-0"
- Description: The construction and characterization of carbon paste ultra-microelectrodes is reported. Besides a disc-shaped electrode, a carbon paste band electrode is studied. It was found that for both electrode configurations steady-state currents were obtained but that with the type of electrode material used for the band electrode, the upper limit of ultra-microelectrode dimensions, which could be used was 100–150 μm. Smaller dimensions for the band electrodes resulted in a high resistance due to the limited conductivity of the carbon paste, when using the optimal paste composition. With cyclic voltammetry, the oxidation of [Fe(CN)6]4− was studied at individual constructed electrodes and at ensembles of individual electrodes. Detection limits of less than 10−6moll−1 were obtained. Using the data of the same curves it was possible to test if the electrodes have errors and about 20% of the constructed electrodes did not pass this test. Finally it was found that these electrodes show good stability.
- Full Text:
- Date Issued: 2001
- Authors: Oni, Joshua , Westbroek, Philippe , Nyokong, Tebello
- Date: 2001
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/291531 , vital:56884 , xlink:href="https://doi.org/10.1016/S1388-2481(01)00212-0"
- Description: The construction and characterization of carbon paste ultra-microelectrodes is reported. Besides a disc-shaped electrode, a carbon paste band electrode is studied. It was found that for both electrode configurations steady-state currents were obtained but that with the type of electrode material used for the band electrode, the upper limit of ultra-microelectrode dimensions, which could be used was 100–150 μm. Smaller dimensions for the band electrodes resulted in a high resistance due to the limited conductivity of the carbon paste, when using the optimal paste composition. With cyclic voltammetry, the oxidation of [Fe(CN)6]4− was studied at individual constructed electrodes and at ensembles of individual electrodes. Detection limits of less than 10−6moll−1 were obtained. Using the data of the same curves it was possible to test if the electrodes have errors and about 20% of the constructed electrodes did not pass this test. Finally it was found that these electrodes show good stability.
- Full Text:
- Date Issued: 2001
- «
- ‹
- 1
- ›
- »