Evaluation of the proposed FDA pilot-dose response methodology for topical corticosteroid bioequivalence testing
- Demana, Patrick H, Smith, Eric W, Walker, Roderick B, Haigh, John M, Kanfer, Isadore
- Authors: Demana, Patrick H , Smith, Eric W , Walker, Roderick B , Haigh, John M , Kanfer, Isadore
- Date: 1997
- Language: English
- Type: Article
- Identifier: vital:6356 , http://hdl.handle.net/10962/d1006047
- Description: The American FDA has recently released a Guidance document for topical corticosteroid bioequivalence testing. The purpose of this study was to evaluate the recommendations of this document for appropriateness. The new specifications require a dose-vasoconstriction response estimation by the use of a Minolta chromameter in a preliminary pilot study to determine the parameters for use in a pivotal bioequivalence study. Methods. The visually-assessed human skin blanching assay methodology routinely practiced in our laboratories was modified to comply with the requirements of the pilot study so that visual and chromameter data could be compared. Two different cream formulations, each containing 0.12% betamethasone 17-valerate, were used for this comparison. Results. Visual data showed the expected rank order of AUC values for most dose durations whereas the chromameter data did not show similar results. The expected rank order of AUC values for both chromameter and visual data was not observed at very short dose durations. In fitting the data to pharmacodynamic models, equivalent goodness of fit criteria were obtained when several different parameter estimates were used in the model definition, however the visual data were best described by the sigmoid E[subscript max] model while the chromameter data were best described by the simple E[subscript max] model. Conclusions. The E[subscript max] values predicted by the models were close to the observed values for both data sets and, in addition, excellent correlation between the AUC values and the maximum blanching response (R[subscript max]) (r > 0.95) was noted for both methods of assessment. The chromameter ED[subscript 50] values determined in this study were approximately 2 hours for both preparations. At this dose duration the instrument would not be sensitive enough to distinguish between weak blanching responses and normal skin for bioequivalence assessment purposes.
- Full Text: false
- Date Issued: 1997
- Authors: Demana, Patrick H , Smith, Eric W , Walker, Roderick B , Haigh, John M , Kanfer, Isadore
- Date: 1997
- Language: English
- Type: Article
- Identifier: vital:6356 , http://hdl.handle.net/10962/d1006047
- Description: The American FDA has recently released a Guidance document for topical corticosteroid bioequivalence testing. The purpose of this study was to evaluate the recommendations of this document for appropriateness. The new specifications require a dose-vasoconstriction response estimation by the use of a Minolta chromameter in a preliminary pilot study to determine the parameters for use in a pivotal bioequivalence study. Methods. The visually-assessed human skin blanching assay methodology routinely practiced in our laboratories was modified to comply with the requirements of the pilot study so that visual and chromameter data could be compared. Two different cream formulations, each containing 0.12% betamethasone 17-valerate, were used for this comparison. Results. Visual data showed the expected rank order of AUC values for most dose durations whereas the chromameter data did not show similar results. The expected rank order of AUC values for both chromameter and visual data was not observed at very short dose durations. In fitting the data to pharmacodynamic models, equivalent goodness of fit criteria were obtained when several different parameter estimates were used in the model definition, however the visual data were best described by the sigmoid E[subscript max] model while the chromameter data were best described by the simple E[subscript max] model. Conclusions. The E[subscript max] values predicted by the models were close to the observed values for both data sets and, in addition, excellent correlation between the AUC values and the maximum blanching response (R[subscript max]) (r > 0.95) was noted for both methods of assessment. The chromameter ED[subscript 50] values determined in this study were approximately 2 hours for both preparations. At this dose duration the instrument would not be sensitive enough to distinguish between weak blanching responses and normal skin for bioequivalence assessment purposes.
- Full Text: false
- Date Issued: 1997
The human skin-blanching assay for comparing topical corticosteroid availability
- Smith, Eric W, Meyer, Eric, Haigh, John M, Maibach, Harold I
- Authors: Smith, Eric W , Meyer, Eric , Haigh, John M , Maibach, Harold I
- Date: 1991
- Language: English
- Type: Article
- Identifier: vital:6433 , http://hdl.handle.net/10962/d1006604
- Description: The human skin blanching assay remains in widespread use as a reliable, qualitative, comparative indicator of topical corticosteroid availability and potency. The experimental refinements promulgated by certain researchers in this field have yielded a versatile bioassay for the accurate assessment of new drugs or delivery vehicles. With the increasing appearance of generic topical corticosteroid formulations which compete with trade-name equivalents, the vital importance of this assay in regulatory affairs and assessing bioequivalence has been re-emphasized. It is stressed that if the blanching assay is to be used in this sphere, then multiple-reading trials must be conducted; important registration or clinical decisions cannot be made with any validity from short-term assessments.
- Full Text:
- Date Issued: 1991
- Authors: Smith, Eric W , Meyer, Eric , Haigh, John M , Maibach, Harold I
- Date: 1991
- Language: English
- Type: Article
- Identifier: vital:6433 , http://hdl.handle.net/10962/d1006604
- Description: The human skin blanching assay remains in widespread use as a reliable, qualitative, comparative indicator of topical corticosteroid availability and potency. The experimental refinements promulgated by certain researchers in this field have yielded a versatile bioassay for the accurate assessment of new drugs or delivery vehicles. With the increasing appearance of generic topical corticosteroid formulations which compete with trade-name equivalents, the vital importance of this assay in regulatory affairs and assessing bioequivalence has been re-emphasized. It is stressed that if the blanching assay is to be used in this sphere, then multiple-reading trials must be conducted; important registration or clinical decisions cannot be made with any validity from short-term assessments.
- Full Text:
- Date Issued: 1991
Sensitivity of different areas of the flexor aspect of the human forearm to corticosteroid-induced skin blanching
- Meyer, Eric, Smith, Eric W, Haigh, John M
- Authors: Meyer, Eric , Smith, Eric W , Haigh, John M
- Date: 1992
- Language: English
- Type: Article
- Identifier: vital:6394 , http://hdl.handle.net/10962/d1006317
- Description: The intensity of corticosteroid-induced blanching has been found to vary at different areas of the flexor aspect of the human forearm. A retrospective analysis of 38,880 observations of skin blanching in 56 volunteers was conducted to assess the sensitivity of forearm skin to betamethasone 17-valerate. The mid-forearm appears to be more sensitive to the blanching response than do the areas close to the wrist or elbow. These results indicate that each preparation under evaluation should be applied to several sites along the forearm when using the human skin blanching assay in order to obtain an accurate comparative assessment of corticosteroid release from topical delivery vehicles.
- Full Text: false
- Date Issued: 1992
- Authors: Meyer, Eric , Smith, Eric W , Haigh, John M
- Date: 1992
- Language: English
- Type: Article
- Identifier: vital:6394 , http://hdl.handle.net/10962/d1006317
- Description: The intensity of corticosteroid-induced blanching has been found to vary at different areas of the flexor aspect of the human forearm. A retrospective analysis of 38,880 observations of skin blanching in 56 volunteers was conducted to assess the sensitivity of forearm skin to betamethasone 17-valerate. The mid-forearm appears to be more sensitive to the blanching response than do the areas close to the wrist or elbow. These results indicate that each preparation under evaluation should be applied to several sites along the forearm when using the human skin blanching assay in order to obtain an accurate comparative assessment of corticosteroid release from topical delivery vehicles.
- Full Text: false
- Date Issued: 1992
In vitro diffusion cell design and validation. I. A stability-indicating high-performance liquid chromatographic assay for betamethasone 17-valerate in purified isopropyl myristate receptor phase
- Smith, Eric W, Haigh, John M
- Authors: Smith, Eric W , Haigh, John M
- Date: 1989
- Language: English
- Type: text , Article
- Identifier: vital:6431 , http://hdl.handle.net/10962/d1006595
- Description: Introduction: The development of a reliable in vitro permeation system necessitates the use of a precise and accurate method of quantifying the amount of permeant partitioning from the membrane into the cell receptor phase. Aqueous donor and receptor chamber fluids have been used in the majority of reported investigations, which makes quantitative permeant analysis relatively facile. Alternatively, radiolabelled diffusants have been used and flux rates monitored by scintillation counting, obviating the need for chromatographic separation of the receptor-phase components. However, this technique is not applicable when nonlabelled compounds or commercial dosage forms are to be evaluated by a cell system. Furthermore, several studies indicate that aqueous receptor phases may not present an optimal partitioning environment for certain lipophilic permeants (1-4), thereby impairing accurate flux monitoring due to limited diffusant solubility. Several attempts have therefore been made to improve the partitioning environment within these systems, by the addition of surfactants for example (4). A lipophilic receptor environment appears beneficial for corticosteroid partitioning, and thus, the use of isopropyl myristate has been investigated because of its bipolar properties that tend to mimic the biochemical composition of the skin (5,6). Betamethasone 17-valerate and its 21-valerate degradation product are highly soluble in isopropyl myristate and this nonaqueous solvent will not augment C-17-to-C-21 ester degradation reactions.
- Full Text:
- Date Issued: 1989
- Authors: Smith, Eric W , Haigh, John M
- Date: 1989
- Language: English
- Type: text , Article
- Identifier: vital:6431 , http://hdl.handle.net/10962/d1006595
- Description: Introduction: The development of a reliable in vitro permeation system necessitates the use of a precise and accurate method of quantifying the amount of permeant partitioning from the membrane into the cell receptor phase. Aqueous donor and receptor chamber fluids have been used in the majority of reported investigations, which makes quantitative permeant analysis relatively facile. Alternatively, radiolabelled diffusants have been used and flux rates monitored by scintillation counting, obviating the need for chromatographic separation of the receptor-phase components. However, this technique is not applicable when nonlabelled compounds or commercial dosage forms are to be evaluated by a cell system. Furthermore, several studies indicate that aqueous receptor phases may not present an optimal partitioning environment for certain lipophilic permeants (1-4), thereby impairing accurate flux monitoring due to limited diffusant solubility. Several attempts have therefore been made to improve the partitioning environment within these systems, by the addition of surfactants for example (4). A lipophilic receptor environment appears beneficial for corticosteroid partitioning, and thus, the use of isopropyl myristate has been investigated because of its bipolar properties that tend to mimic the biochemical composition of the skin (5,6). Betamethasone 17-valerate and its 21-valerate degradation product are highly soluble in isopropyl myristate and this nonaqueous solvent will not augment C-17-to-C-21 ester degradation reactions.
- Full Text:
- Date Issued: 1989